D-Link DIS-200G Emulator - Page 158

emitted by the same object instance., Binding objects

Page 158 highlights

DIS-200G Series Industrial Gigabit Ethernet Smart Managed Switch to the Forwarding state, or from the Forwarding state to the Blocking state. The trap is not sent if a newRoot trap is sent for the same transition. Implementation of this trap is optional PoE Trap Name Description OID pethMainPowerUsageOn Notification This trap indicates PSE Threshold usage indication is on, the usage power is above the threshold. At least 500 msec must elapse between notifications being emitted by the same object instance. Binding objects: (1) pethMainPseConsumptionPower 1.3.6.1.2.1.105. 0.2 pethMainPowerUsageOff Notification This trap indicates PSE Threshold usage indication is off, the usage power is below the threshold. At least 500 msec must elapse between notifications being emitted by the same object instance. Binding objects: (1) pethMainPseConsumptionPower 1.3.6.1.2.1.105. 0.3 isPoeIfPdAliveFailOccurN otification This Notification indicates if the PD device has the stop working or no response problem. 1.3.6.1.4.1.171. 11.155.1000.24. 0.4 Port Trap Name linkUp linkDown Description A notification is generated when port linkup. Binding objects: (1) ifIndex (2) ifAdminStatus (3) ifOperStatu A notification is generated when port linkdown. Binding objects: (1) ifIndex (2) ifAdminStatus 147 OID 1.3.6.1.6.3.1.1.5 .4 1.3.6.1.6.3.1.1.5 .3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161

DIS-200G Series Industrial Gigabit Ethernet Smart Managed Switch
147
to the Forwarding state, or from the Forwarding state
to the Blocking state. The trap is not sent if a newRoot
trap is sent for the same transition. Implementation of
this trap is optional
PoE
Trap Name
Description
OID
pethMainPowerUsageOn
Notification
This trap indicates PSE Threshold usage indication is
on, the usage power is above the threshold. At least
500 msec must elapse between notifications being
emitted by the same object instance.
Binding objects:
(1) pethMainPseConsumptionPower
1.3.6.1.2.1.105.
0.2
pethMainPowerUsageOff
Notification
This trap indicates PSE Threshold usage indication is
off, the usage power is below the threshold. At least
500 msec must elapse between notifications being
emitted by the same object instance.
Binding objects:
(1) pethMainPseConsumptionPower
1.3.6.1.2.1.105.
0.3
isPoeIfPdAliveFailOccurN
otification
This Notification indicates if the PD device has the stop
working or no response problem.
1.3.6.1.4.1.171.
11.155.1000.24.
0.4
Port
Trap Name
Description
OID
linkUp
A notification is generated when port linkup.
Binding objects:
(1) ifIndex
(2) ifAdminStatus
(3) ifOperStatu
1.3.6.1.6.3.1.1.5
.4
linkDown
A notification is generated when port linkdown.
Binding objects:
(1) ifIndex
(2) ifAdminStatus
1.3.6.1.6.3.1.1.5
.3