D-Link DIS-200G Emulator - Page 83

Profile Name, Apply, Delete, Revertive, Guard Timer, Hold-Off Timer, WTR Timer,

Page 83 highlights

DIS-200G Series Industrial Gigabit Ethernet Smart Managed Switch Figure 6-45 ERPS Profile window The fields that can be configured are described below: Parameter Profile Name Description Enter the G.8032 profile's name here. This name can be up to 32 characters long. Multiple ERP instances can be associated with the same G.8032 profile. The instances associated with the same profile protect the same set of VLANs, or the VLANs protected by one instance are a subset of LANs protected by another instance. Click the Apply button to associate the G.8032 profile with the ERP instance created. Click the Delete button to disassociate the G.8032 profile based on the Profile Name entered. Click the Edit button to modify the specified G.8032 profile. After click the Edit button, the following window will appear. Figure 6-46 ERPS Profile (Edit) window The fields that can be configured are described below: Parameter Revertive Guard Timer Hold-Off Timer WTR Timer Description Select the checkbox and then select the revertive state. Options to choose from are Enable and Disabled. This function is used to revert back to the working transport entity, for example, when the RPL was blocked. Select the checkbox and enter the guard timer value here. This value must be between 10 and 2000 milliseconds. By default, this value is 500 milliseconds. Select the checkbox and enter hold-off timer value here. This value must be between 0 and 10 seconds. By default, this value is 0 seconds Select the checkbox and enter the WTR timer value here. This value must be between 1 and 12 minutes. By default, this value is 5 minutes. Click the Back button to discard the changes made and return to the previous window. Click the Apply button to accept the changes made. 76

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161

DIS-200G Series Industrial Gigabit Ethernet Smart Managed Switch
76
The fields that can be configured are described below:
Parameter
Description
Profile Name
Enter the G.8032 profile’s name here. This name can be up to 32
characters long. Multiple ERP instances can be associated with
the same G.8032 profile. The instances associated with the same
profile protect the same set of VLANs, or the VLANs protected by
one instance are a subset of LANs protected by another instance.
Click the
Apply
button to associate the G.8032 profile with the ERP instance created.
Click the
Delete
button to disassociate the G.8032 profile based on the
Profile Name
entered.
Click the
Edit
button to modify the specified G.8032 profile.
After click the
Edit
button, the following window will appear.
The fields that can be configured are described below:
Parameter
Description
Revertive
Select the checkbox and then select the revertive state. Options to
choose from are Enable and Disabled. This function is used to
revert back to the working transport entity, for example, when the
RPL was blocked.
Guard Timer
Select the checkbox and enter the guard timer value here. This
value must be between 10 and 2000 milliseconds. By default, this
value is 500 milliseconds.
Hold-Off Timer
Select the checkbox and enter hold-off timer value here. This value
must be between 0 and 10 seconds. By default, this value is 0
seconds
WTR Timer
Select the checkbox and enter the WTR timer value here. This
value must be between 1 and 12 minutes. By default, this value is
5 minutes.
Click the
Back
button to discard the changes made and return to the previous window.
Click the
Apply
button to accept the changes made.
Figure 6-45
ERPS Profile window
Figure 6-46
ERPS Profile (Edit) window