HP 6125XLG R2306-HP 6125XLG Blade Switch FCoE Configuration Guide - Page 42
Verifying the configurations, Create interface VFC 2, and con it to operate in E mode.
View all HP 6125XLG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
[SwitchB-Ten-GigabitEthernet1/1/5] quit # Create interface VFC 1, configure it to operate in F mode, bind it to interface Ten-GigabitEthernet 1/1/5, and assign it to VSAN 1 as a trunk port. [SwitchB] interface vfc 1 [SwitchB-Vfc1] fc mode f [SwitchB-Vfc1] bind interface ten-gigabitethernet 1/1/5 [SwitchB-Vfc1] port trunk vsan 1 [SwitchB-Vfc1] quit # Assign interface Ten-GigabitEthernet 1/1/5 to VLAN 10 as a trunk port. [SwitchB] interface ten-gigabitethernet 1/1/5 [SwitchB-Ten-GigabitEthernet1/1/5] port link-type trunk [SwitchB-Ten-GigabitEthernet1/1/5] port trunk permit vlan 10 [SwitchB-Ten-GigabitEthernet1/1/5] quit # Create interface VFC 2, and configure it to operate in E mode. [SwitchB] interface vfc 2 [SwitchB-Vfc2] fc mode e # Bind interface VFC 2 to interface Ten-GigabitEthernet 1/1/6, and assign it to VSAN 1 as a trunk port. [SwitchB-Vfc2] bind interface ten-gigabitethernet 1/1/6 [SwitchB-Vfc2] port trunk vsan 1 [SwitchB-Vfc2] quit # Assign interface Ten-GigabitEthernet 1/1/6 to VLAN 10 as a trunk port. [SwitchB] interface ten-gigabitethernet 1/1/6 [SwitchB-Ten-GigabitEthernet1/1/6] port link-type trunk [SwitchB-Ten-GigabitEthernet1/1/6] port trunk permit vlan 10 [SwitchB-Ten-GigabitEthernet1/1/6] quit # Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1. [SwitchB] vlan 10 [SwitchB-vlan10] fcoe enable vsan 1 [SwitchB-vlan10] quit Verifying the configurations 1. Verify the configurations on Switch A. [SwitchA] display fc domain vsan 1 Domain Information of VSAN 1: Running time information: State: Stable Switch WWN: 48:33:43:2d:46:43:1A:1A Fabric name: 11:11:11:11:11:11:11:11 Priority: 128 Domain ID: 1 Configuration information: Domain configure: Disabled Domain auto-reconfigure: Disabled Fabric name: 11:11:11:11:11:11:11:11 36