HP 6125XLG R2306-HP 6125XLG Blade Switch FCoE Configuration Guide - Page 76

On Switch A, use the, command to ping Switch B and check whether Switch B is reachable.

Page 76 highlights

Routing Table: VSAN 2 Destinations : 5 Routes : 5 Destination/mask Protocol Preference 0x020000/8 FSPF 20 0xfffc01/24 DIRECT 0 0xfffffa/24 DIRECT 0 0xfffffc/24 DIRECT 0 0xfffffd/24 DIRECT 0 Cost 265 0 0 0 0 Interface Vfc1 InLoop0 InLoop0 InLoop0 InLoop0 # On Switch A, use the fcping command to ping Switch B and check whether Switch B is reachable. [SwitchA] fcping fcid fffc02 vsan 2 FCPING fcid 0xfffc02: 128 data bytes, press CTRL_C to break. Reply from 0xfffc02: bytes = 128 time = 1.102 ms Reply from 0xfffc02: bytes = 128 time = 0.276 ms Reply from 0xfffc02: bytes = 128 time = 0.253 ms Reply from 0xfffc02: bytes = 128 time = 0.270 ms Reply from 0xfffc02: bytes = 128 time = 0.247 ms --- 0xfffc02 fcping statistics --5 packet(s) transmitted 5 packet(s) received 0.00% packet loss round-trip min/avg/max = 0.247/0.430/1.102 ms The output shows that Switch A can reach Switch B. 70

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

70
Routing Table: VSAN 2
Destinations : 5
Routes : 5
Destination/mask
Protocol
Preference
Cost
Interface
0x020000/8
FSPF
20
265
Vfc1
0xfffc01/24
DIRECT
0
0
InLoop0
0xfffffa/24
DIRECT
0
0
InLoop0
0xfffffc/24
DIRECT
0
0
InLoop0
0xfffffd/24
DIRECT
0
0
InLoop0
# On Switch A, use the
fcping
command to ping Switch B and check whether Switch B is reachable.
[SwitchA] fcping fcid fffc02 vsan 2
FCPING fcid 0xfffc02: 128 data bytes, press CTRL_C to break.
Reply from 0xfffc02: bytes = 128 time = 1.102 ms
Reply from 0xfffc02: bytes = 128 time = 0.276 ms
Reply from 0xfffc02: bytes = 128 time = 0.253 ms
Reply from 0xfffc02: bytes = 128 time = 0.270 ms
Reply from 0xfffc02: bytes = 128 time = 0.247 ms
--- 0xfffc02 fcping statistics ---
5 packet(s) transmitted
5 packet(s) received
0.00% packet loss
round-trip min/avg/max = 0.247/0.430/1.102 ms
The output shows that Switch A can reach Switch B.