HP 6125XLG R2306-HP 6125XLG Blade Switch FCoE Configuration Guide - Page 57

the two interfaces to trust the 802.1p priority carried in packets., Create interface VFC 1

Page 57 highlights

[SwitchA-maptbl-out-dot1p-lp] import 3 export 3 [SwitchA-maptbl-out-dot1p-lp] quit # Enable byte-count WRR on Ten-GigabitEthernet 1/1/5 and Ten-GigabitEthernet 1/1/6, and configure queue 3 to use SP queuing. [SwitchA] interface ten-gigabitethernet 1/1/5 [SwitchA-Ten-GigabitEthernet1/1/5] qos wrr byte-count [SwitchA-Ten-GigabitEthernet1/1/5] qos wrr 3 group sp [SwitchA-Ten-GigabitEthernet1/1/5] quit [SwitchA] interface ten-gigabitethernet 1/1/6 [SwitchA-Ten-GigabitEthernet1/1/6] qos wrr byte-count [SwitchA-Ten-GigabitEthernet1/1/6] qos wrr 3 group sp [SwitchA-Ten-GigabitEthernet1/1/6] quit # Enable Ten-GigabitEthernet 1/1/5 and Ten-GigabitEthernet 1/1/6 to automatically negotiate with their peers to decide whether to enable PFC, enable PFC for 802.1p priority 3, and configure the two interfaces to trust the 802.1p priority carried in packets. [SwitchA] interface ten-gigabitethernet 1/1/5 [SwitchA-Ten-GigabitEthernet1/1/5] priority-flow-control auto [SwitchA-Ten-GigabitEthernet1/1/5] priority-flow-control no-drop dot1p 3 [SwitchA-Ten-GigabitEthernet1/1/5] qos trust dot1p [SwitchA-Ten-GigabitEthernet1/1/5] quit [SwitchA] interface ten-gigabitethernet 1/1/6 [SwitchA-Ten-GigabitEthernet1/1/6] priority-flow-control auto [SwitchA-Ten-GigabitEthernet1/1/6] priority-flow-control no-drop dot1p 3 [SwitchA-Ten-GigabitEthernet1/1/6] qos trust dot1p [SwitchA-Ten-GigabitEthernet1/1/6] quit # Create interface VFC 1, and configure it to operate in F mode. [SwitchA] interface vfc 1 [SwitchA-Vfc1] fc mode f # Bind interface VFC 1 to interface Ten-GigabitEthernet 1/1/5, and assign it to VSAN 10 as a trunk port. [SwitchA-Vfc1] bind interface ten-gigabitethernet 1/1/5 [SwitchA-Vfc1] port trunk vsan 10 [SwitchA-Vfc1] quit # Assign interface Ten-GigabitEthernet 1/1/5 to VLAN 10 as a trunk port. [SwitchA] interface ten-gigabitethernet 1/1/5 [SwitchA-Ten-GigabitEthernet1/1/5] port link-type trunk [SwitchA-Ten-GigabitEthernet1/1/5] port trunk permit vlan 10 [SwitchA-Ten-GigabitEthernet1/1/5] quit # Create interface VFC 2, and configure it to operate in F mode. [SwitchA] interface vfc 2 [SwitchA-Vfc2] fc mode f # Bind interface VFC 2 to interface Ten-GigabitEthernet 1/1/6, and assign it to VSAN 20 as a trunk port. [SwitchA-Vfc2] bind interface ten-gigabitethernet 1/1/6 [SwitchA-Vfc2] port trunk vsan 20 [SwitchA-Vfc2] quit # Assign interface Ten-GigabitEthernet 1/1/6 to VLAN 20 as a trunk port. 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

51
[SwitchA-maptbl-out-dot1p-lp] import 3 export 3
[SwitchA-maptbl-out-dot1p-lp] quit
# Enable byte-count WRR on Ten-GigabitEthernet 1/1/5 and Ten-GigabitEthernet 1/1/6, and
configure queue 3 to use SP queuing.
[SwitchA] interface ten-gigabitethernet 1/1/5
[SwitchA-Ten-GigabitEthernet1/1/5] qos wrr
byte-count
[SwitchA-Ten-GigabitEthernet1/1/5] qos wrr 3 group sp
[SwitchA-Ten-GigabitEthernet1/1/5] quit
[SwitchA] interface ten-gigabitethernet 1/1/6
[SwitchA-Ten-GigabitEthernet1/1/6] qos wrr
byte-count
[SwitchA-Ten-GigabitEthernet1/1/6] qos wrr 3 group sp
[SwitchA-Ten-GigabitEthernet1/1/6] quit
# Enable Ten-GigabitEthernet 1/1/5 and Ten-GigabitEthernet 1/1/6 to automatically negotiate
with their peers to decide whether to enable PFC, enable PFC for 802.1p priority 3, and configure
the two interfaces to trust the 802.1p priority carried in packets.
[SwitchA] interface ten-gigabitethernet 1/1/5
[SwitchA-Ten-GigabitEthernet1/1/5] priority-flow-control auto
[SwitchA-Ten-GigabitEthernet1/1/5] priority-flow-control no-drop dot1p 3
[SwitchA-Ten-GigabitEthernet1/1/5] qos trust dot1p
[SwitchA-Ten-GigabitEthernet1/1/5] quit
[SwitchA] interface ten-gigabitethernet 1/1/6
[SwitchA-Ten-GigabitEthernet1/1/6] priority-flow-control auto
[SwitchA-Ten-GigabitEthernet1/1/6] priority-flow-control no-drop dot1p 3
[SwitchA-Ten-GigabitEthernet1/1/6] qos trust dot1p
[SwitchA-Ten-GigabitEthernet1/1/6] quit
# Create interface VFC 1, and configure it to operate in F mode.
[SwitchA] interface vfc 1
[SwitchA-Vfc1] fc mode f
# Bind interface VFC 1 to interface Ten-GigabitEthernet 1/1/5, and assign it to VSAN 10 as a
trunk port.
[SwitchA-Vfc1] bind interface ten-gigabitethernet 1/1/5
[SwitchA-Vfc1] port trunk vsan 10
[SwitchA-Vfc1] quit
# Assign interface Ten-GigabitEthernet 1/1/5 to VLAN 10 as a trunk port.
[SwitchA] interface ten-gigabitethernet 1/1/5
[SwitchA-Ten-GigabitEthernet1/1/5] port link-type trunk
[SwitchA-Ten-GigabitEthernet1/1/5] port trunk permit vlan 10
[SwitchA-Ten-GigabitEthernet1/1/5] quit
# Create interface VFC 2, and configure it to operate in F mode.
[SwitchA] interface vfc 2
[SwitchA-Vfc2] fc mode f
# Bind interface VFC 2 to interface Ten-GigabitEthernet 1/1/6, and assign it to VSAN 20 as a
trunk port.
[SwitchA-Vfc2] bind interface ten-gigabitethernet 1/1/6
[SwitchA-Vfc2] port trunk vsan 20
[SwitchA-Vfc2] quit
# Assign interface Ten-GigabitEthernet 1/1/6 to VLAN 20 as a trunk port.