HP 6125XLG R2306-HP 6125XLG Blade Switch FCoE Configuration Guide - Page 51
Verifying the configurations, Display the domain information of VSAN 1 on Switch A.
View all HP 6125XLG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
# Assign interface Ten-GigabitEthernet 1/1/6 to VLAN 10 as a trunk port. [SwitchD] interface ten-gigabitethernet 1/1/6 [SwitchD-Ten-GigabitEthernet1/1/6] port link-type trunk [SwitchD-Ten-GigabitEthernet1/1/6] port trunk permit vlan 10 [SwitchD-Ten-GigabitEthernet1/1/6] quit # Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1. [SwitchD] vlan 10 [SwitchD-vlan10] fcoe enable vsan 1 [SwitchD-vlan10] quit Verifying the configurations # Display the domain information of VSAN 1 on Switch A. [SwitchA] display fc domain vsan 1 Domain Information of VSAN 1: Running time information: State: Stable Switch WWN: 48:33:43:2d:46:43:1A:1A Fabric name: 48:33:43:2d:46:43:1B:1B Priority: 128 Domain ID: 11 Configuration information: Domain configure: Enabled Domain auto-reconfigure: Disabled Fabric name: 48:33:43:2d:46:43:1A:1A Priority: 128 Domain ID: 11 (preferred) Principal switch running time information: Priority: 1 Path Upstream Downstream Interface Vfc1 Vfc2 The output shows that the domain configuration is complete and that the principal switch assigns domain ID 11 to Switch A. # Display the domain ID list of VSAN 1 on Switch A. [SwitchA] display fc domain-list vsan 1 Domain list of VSAN 1: Number of domains: 4 Domain ID 0x01(1) 0x0b(11) 0x0d(13) 0x0e(14) WWN 48:33:43:2d:46:43:1B:1B [Principal] 48:33:43:2d:46:43:1A:1A [Local] 48:33:43:2d:46:43:1C:1C 48:33:43:2d:46:43:1D:1D 45