IBM 9228 Service Guide - Page 122

Run the Configuration/Setup Utility program

Page 122 highlights

Table 7. POST error codes (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, Type 9228 and 9232," on page 19 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 00019502 Microprocessor 1 failed. 1. (Trained service technician only) Reseat the microprocessor. 2. Replace the following components one at a time, in the order shown, restarting the computer each time: a. (Trained service technician only) Microprocessor b. (Trained service technician only) System board 00019xxx Microprocessor x is not functioning. 1. Make sure that microprocessor x is installed correctly. 2. Replace the following components one at a time, in the order shown, restarting the computer each time: a. (Trained service technician only) Microprocessor x b. VRM if installed c. (Trained service technician only) System board 00151200 Unrecoverable error, microprocessor x reported IERR. 1. (Trained service technician only) Reseat the microprocessor. 2. Replace the following components one at a time, in the order shown, restarting the computer each time: a. (Trained service technician only) Microprocessor x b. VRM if installed c. (Trained service technician only) System board 00180100 A PCI adapter has requested memory resources that are not available. 1. Run the Configuration/Setup Utility program. 2. Reseat each adapter. Note: If an error LED is lit on an adapter, reseat that adapter first. If no LEDs are lit, reseat each adapter one at a time, restarting the computer each time to isolate the failing adapter. 3. Replace the following components one at a time, in the order shown, restarting the computer each time: a. Failing adapter b. (Trained service technician only) System board 104 IBM IntelliStation Z Pro Type 9228 and 9232: Problem Determination and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184

Table 7. POST error codes (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 9228 and 9232,” on page 19 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
00019502
Microprocessor 1 failed.
1.
(Trained service technician only) Reseat the
microprocessor.
2.
Replace the following components one at a time,
in the order shown, restarting the computer each
time:
a.
(Trained service technician only)
Microprocessor
b.
(Trained service technician only) System board
00019xxx
Microprocessor x is not functioning.
1.
Make sure that microprocessor x is installed
correctly.
2.
Replace the following components one at a time,
in the order shown, restarting the computer each
time:
a.
(Trained service technician only)
Microprocessor x
b.
VRM if installed
c.
(Trained service technician only) System board
00151200
Unrecoverable error, microprocessor x
reported IERR.
1.
(Trained service technician only) Reseat the
microprocessor.
2.
Replace the following components one at a time,
in the order shown, restarting the computer each
time:
a.
(Trained service technician only)
Microprocessor x
b.
VRM if installed
c.
(Trained service technician only) System board
00180100
A PCI adapter has requested memory
resources that are not available.
1.
Run the Configuration/Setup Utility program.
2.
Reseat each adapter.
Note:
If an error LED is lit on an adapter, reseat
that adapter first. If no LEDs are lit, reseat each
adapter one at a time, restarting the computer
each time to isolate the failing adapter.
3.
Replace the following components one at a time,
in the order shown, restarting the computer each
time:
a.
Failing adapter
b.
(Trained service technician only) System board