IBM 9228 Service Guide - Page 145
Adapter Local RAM test error
UPC - 000435947840
View all IBM 9228 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 145 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, Type 9228 and 9232," on page 19 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 035-267-0nn Adapter Local RAM test error. 1. Update the ServeRAID adapter firmware (see "Updating the firmware" on page 13). 2. Reseat the ServeRAID adapter. 3. Replace the ServeRAID adapter. 035-268-0nn Adapter NVSRAM test error. 1. Update the ServeRAID adapter firmware (see "Updating the firmware" on page 13). 2. Reseat the ServeRAID adapter. 3. Replace the ServeRAID adapter. 035-269-0nn Adapter Cache test error. 1. Update the ServeRAID adapter firmware (see "Updating the firmware" on page 13). 2. Reseat the ServeRAID adapter. 3. Replace the ServeRAID adapter. 035-271-0nn Adapter XOR engine test error. 1. Update the ServeRAID adapter firmware (see "Updating the firmware" on page 13). 2. Reseat the ServeRAID adapter. 3. Replace the ServeRAID adapter. 035-272-0nn Adapter Drive test error. Replace the attached drive. 035-273-0nn Adapter Drive error. Replace the attached drive. 035-274-0nn Adapter Parameters set error. 1. Update the ServeRAID adapter firmware (see "Updating the firmware" on page 13). 2. Reseat the ServeRAID adapter. 3. Replace the ServeRAID adapter. 035-275-001 Adapter Communication error. 1. Update the ServeRAID adapter firmware (see "Updating the firmware" on page 13). 2. Reseat the ServeRAID adapter. 3. Replace the ServeRAID adapter. 035-276-001 Adapter CPU test error. 1. Update the ServeRAID adapter firmware (see "Updating the firmware" on page 13). 2. Reseat the ServeRAID adapter. 3. Replace the ServeRAID adapter. 035-277-001 Adapter Local RAM test error. 1. Update the ServeRAID adapter firmware (see "Updating the firmware" on page 13). 2. Reseat the ServeRAID adapter. 3. Replace the ServeRAID adapter. 035-278-001 Adapter NVSRAM test error. 1. Update the ServeRAID adapter firmware (see "Updating the firmware" on page 13). 2. Reseat the ServeRAID adapter. 3. Replace the ServeRAID adapter. Chapter 5. Diagnostics 127