IBM 9228 Service Guide - Page 97
from the suction cup., Squeeze the bladder of the vacuum tool to release the microprocessor
UPC - 000435947840
View all IBM 9228 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
Vacuum tool Microprocessor Socket Figure 55. Installing the microprocessor a. Squeeze and hold the bladder of the vacuum tool; then, place the suction cup on the microprocessor and release the bladder (see Figure 55). Note: To maintain the correct orientation between the microprocessor and the microprocessor socket during installation, observe the following information: v The microprocessor has two notches that are keyed to two tabs on the sides of the socket. v A triangle-shaped indicator on one corner of the microprocessor points to a 45-degree angle on one corner of the socket. b. Using the vacuum tool, carefully place the microprocessor into the socket. c. Squeeze the bladder of the vacuum tool to release the microprocessor from the suction cup. 3. Close the microprocessor bracket frame; then, close the microprocessor retention latch and lock it securely in place (see Figure 56). Figure 56. Microprocessor bracket frame 4. Install the fan sink. a. Make sure that the fan-sink retention lever is in the fully open position. Chapter 4. Removing and replacing computer components 79