IBM 9228 Service Guide - Page 123
Action, Table 7. POST error codes continued
UPC - 000435947840
View all IBM 9228 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 123 highlights
Table 7. POST error codes (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, Type 9228 and 9232," on page 19 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 00180200 No more I/O space is available for the PCI adapter. 1. Run the Configuration/Setup Utility program. 2. Reseat each adapter. Note: If an error LED is lit on an adapter, reseat that adapter first. If no LEDs are lit, reseat each adapter one at a time, restarting the computer each time to isolate the failing adapter. 3. Replace the following components one at a time, in the order shown, restarting the computer each time: a. Failing adapter b. (Trained service technician only) System board 00180300 There is no memory available above 1MB for the PCI adapter. 1. Run the Configuration/Setup Utility program. 2. Reseat each adapter. Note: If an error LED is lit on an adapter, reseat that adapter first. If no LEDs are lit, reseat each adapter one at a time, restarting the computer each time to isolate the failing adapter. 3. Replace the following components one at a time, in the order shown, restarting the computer each time: a. Failing adapter b. (Trained service technician only) System board 00180400 There is no memory available below 1MB for the PCI adapter. 1. Run the Configuration/Setup Utility program. 2. Reseat each adapter. Note: If an error LED is lit on an adapter, reseat that adapter first. If no LEDs are lit, reseat each adapter one at a time, restarting the computer each time to isolate the failing adapter. 3. Replace the following components one at a time, in the order shown, restarting the computer each time: a. Failing adapter b. (Trained service technician only) System board 00180500 PCI option read-only memory checksum error. 1. Reseat each adapter. Note: If an error LED is lit on an adapter, reseat that adapter first. If no LEDs are lit, reseat each adapter one at a time, restarting the computer each time to isolate the failing adapter. 2. Replace the following components one at a time, in the order shown, restarting the computer each time: a. Failing adapter b. (Trained service technician only) System board Chapter 5. Diagnostics 105