IBM x3400 Installation Guide - Page 86

Description

Page 86 highlights

Table 7. Abbreviated list of POST error codes (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 1604 Machine Type mismatch detected. 1. Update the BIOS code and make sure that the correct machine type information for the server is correct. 2. Update the BMC firmware. 3. (Trained service technician only) Replace the system board. 1762 Fixed disk configuration error. 1. Run the Configuration/Setup Utility program and load the default settings. 2. Reseat the following components: a. SATA or SAS cable b. Reseat the hard disk drive c. (Trained service technician only) Reseat the system board. d. Replace the components listed in step 2 one at a time, in the order shown, restarting the server each time. 72 System x3400 Types 7973, 7974, 7975, and 7976: Installation Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

Table
7.
Abbreviated
list
of
POST
error
codes
(continued)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
1604
Machine
Type
mismatch
detected.
1.
Update
the
BIOS
code
and
make
sure
that
the
correct
machine
type
information
for
the
server
is
correct.
2.
Update
the
BMC
firmware.
3.
(Trained
service
technician
only)
Replace
the
system
board.
1762
Fixed
disk
configuration
error.
1.
Run
the
Configuration/Setup
Utility
program
and
load
the
default
settings.
2.
Reseat
the
following
components:
a.
SATA
or
SAS
cable
b.
Reseat
the
hard
disk
drive
c.
(Trained
service
technician
only)
Reseat
the
system
board.
d.
Replace
the
components
listed
in
step
2
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
72
System
x3400
Types
7973,
7974,
7975,
and
7976:
Installation
Guide