Page 68 highlights
Chapter 3 - Use the Scanner UPC-E Options Setting Number system transmission Check digit User defined symbology ID Code mark Description Enables or disables transmission of the UPC-E number system character. Default is enabled. Enables or disables reading the check digit. Default is enabled. Sets the symbology ID for UPC-E. Range is 1 to 4 ASCII characters. \xFF is not supported. Default is E0. A one-character code mark that serves as an identifier for UPC-E. Default is E. EAN-8 Options Setting Check digit User defined symbology ID Code mark Description Enables or disables reading the check digit. Default is enabled. Sets the symbology ID for EAN-8. Range is 1 to 4 ASCII characters. \xFF is not supported. Default is FF. A one-character code mark that serves as an identifier for EAN-8. Default is N. EAN-13 Options Setting Check digit ISBN conversion ISMN conversion ISSN conversion Description Enables or disables reading the check digit. Default is enabled. Enables or disables conversion of EAN-13 data to ISBN format. Default is disabled. Enables or disables conversion of EAN-13 data to ISMN format. Default is disabled. Enables or disables conversion of EAN-13 data to ISSN format. Default is disabled. 56 CN51 Mobile Computer User Manual