GS1 DataBar Expanded Settings, GS1 Composite A/B Settings and Descriptions
View all Intermec CN51 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 70 highlights
Chapter 3 - Use the Scanner GS1 Composite A/B Settings and Descriptions Setting User defined symbology ID Code mark Description Sets the symbology ID. Range is 1 to 4 ASCII characters. \xFF is not supported. Default is G0. A one-character code mark that serves as an identifier. Default is *. GS1 Composite C Settings and Descriptions Setting User defined symbology ID Code mark Description Sets the symbology ID. Range is 1 to 4 ASCII characters. \xFF is not supported. Default is G1. A one-character code mark that serves as an identifier. Default is *. GS1 DataBar Expanded Settings This section lists all configurable settings for decoding the GS1 DataBar Expanded symbology. GS1 DataBar Expanded Settings and Descriptions Setting User defined symbology ID Code mark Description Sets the symbology ID for GS1 DataBar Expanded. Range is 1 to 4 ASCII characters. \xFF is not supported. Default is C5. A one-character code mark that serves as an identifier for GS1 DataBar Expanded. Default is *. 58 CN51 Mobile Computer User Manual