Oki OKIPOS408II OKIPOS 408II Programmer s Technical Reference - Page 303
Status Transmission Condition Settings, Specs. A, B
View all Oki OKIPOS408II manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 303 highlights
3-3-6 Status ESC RS a n [Name] [Code] Set status transmission conditions ASCII ESC RS a n Hex. 1B 1E 61 n Decimal 27 30 97 n [Defined Area] Specs. A, B 0 ≤ n ≤ 3, 48≤n≤51 ("0"≤n≤"3") Spec. C 0≤n≤3, 48 ≤ n ≤ 51 ("0" ≤ n ≤ "3") [Initial Value] DIP Switch / Memory switch setting [Function] Sets the status transmission conditions. See Appendix 3 for details regarding ASB status. 1. Specification A n Status Transmission Conditions 0, 48 ASB invalid 1, 49 ASB valid 2. Specification B n Status Transmission Condition Settings 0, 48 ASB invalid 1, 49 ASB valid 3. Specification C n Status Transmission Condition Settings 0, 48 1, 49 2, 50 3, 51 ASB invalid and NSB invalid ASB valid and NSB invalid ASB invalid and NSB valid ASB valid and NSB valid _____ STAR Page Mode Command Specifications 3-62