Oki OKIPOS408II OKIPOS 408II Programmer s Technical Reference - Page 338
Appendix 3 Status Specifications, ENQ Command Status, Reception Buffer Overflow
View all Oki OKIPOS408II manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 338 highlights
5-3 Appendix 3 Status Speci cations 5-3-1 ENQ Command Status This status is the one the printer transmits using the ENQ command. B it C ontents S tatus B y Model "0" "1" 408 TUP900 TSP1000 TSP828L TUP500 408II 7 Conversion SW OPEN CLOSE × × × × 6 Reception Bu er Over ow Does not occur Occurs 5 Reception Bu er Empty Has Data Empty 4 Fixed at "0" - - - - - - - 3 Paper end Paper No paper 2 Other Errors No Error Error 1 Framing Error No Error Error 0 Parity Error No Error Error • Reception Bu er Over ow/Framing Error/Parity Error These errors are cleared after holding that the error occurred and using this command to inquire the status and the error status is sent. • Other Errors Indicates non-recoverable errors and cover open error. 5-3-2 EOT Command Status This status is the one the printe r transmits using the EOT command. B it C ontents S tatus B y Model "0" "1" 408 TUP900 TSP1000 TSP828L TUP500 408II 7 Fixed at "0" - - - - - - - 6 Paper jam at presenter No Error Error × × × × Paper Near-end (Outer 5 Side) Paper No paper × × × × × × 4 Fixed at "1" - - - - - - - 3 Paper end Paper No paper Paper Near-end Paper No paper x 2 (Inner Side) 1 BM Error No Error Error × 0 Fixed at "0" • BM Error - - - - - - - On models that use a common PE and BM sensor, if a continuous error is detected beyond a determined amount, it indicates not a black mark error, but a paper out error. _____ STAR Page Mode Command Speci cations 5-11