Panasonic AJHPX2700G AJHPX2700G User Guide - Page 82

P2 Card Remaining Free Space/capacity Indication, P2CARD REMAIN

Page 82 highlights

Information Item 36. B.GAMMA RANGE 37. Switch lock setting 38. Exposure Indication Indication 1 2 3 !SW LOCK -4 -3„„ -3„ -3 -2„„ -2„ -2 -1„„ -1„ -1 ±0 +0„ +0„„ +1 +1„ +1„„ +2 +2„ +2„„ +3 +3„ +3„„ +4 +4„ +4„„ +5 Status This indicates the level (upper limit) of the compression/expansion. This is displayed when any of the side switches (GAIN, OUTPUT and AWB switches) are operated with SIDE SW LOCK in a locked state. Note that it is not displayed during when AJ-RC10G is connected and in operation. When GAMMA MODE SEL has been set to "FILM-REC" and STATUS MODE to "FILM REC", executing the Y GET operation measures brightness in proximity to the center marker. The measured value is displayed as an exposure level. A measured output signal of 30% is displayed as ±0 (normal). This value is then adjusted by +1 STOP for every doubling of the amount of incident light and by -1 STOP for every halving of the amount incident light. Each „ represents 1/3 STOP. GAMMA MODE SEL is set from the screen of the PAINT page. STATUS MODE is set from the screen of the VF page. P2 Card Remaining Free Space/capacity Indication Status of unit Recording status Under normal Other than conditions LOOP REC mode LOOP REC mode During MODE Other than CHECK LOOP REC mode LOOP REC mode Menu option P2CARD REMAIN*1 TOTAL ONE-CARD OFF TOTAL/ONE-CARD OFF TOTAL/ONE-CARD/ OFF 5. P2 card remaining free space indication*2 6. P2 card remaining free space indication (during MODE CHECK)*2 The total remaining free space of all P2 cards loaded in the P2 card slots is indicated in minutes. Example: 30min Not provided The number of the P2 card slot holding the Not provided target P2 card, together with that card's remaining free space indicated in minutes. Example: 8min Not provided Not provided Indicated as "LOOP" Not provided Not provided Not provided The total remaining free space and capacities of all P2 cards loaded in the P2 card slots are indicated in minutes. Example: 20/40 The number of the P2 card slot holding the target P2 card, together with that card's remaining free space, indicated in minutes. Example: 8min Indicated as "LOOP" The estimated recording time is indicated in minutes. Example: 7min *1 The menu option P2CARD REMAIN can be found in the screen on the VF page. *2 If the remaining free space or memory capacity is 9999 min or more, [9999min] is displayed. 82 Adjustments and Settings for Recording: Viewfinder Screen Status Displays

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206

82
Adjustments and Settings for Recording
: Viewfinder Screen Status Displays
*1
The menu option P2CARD REMAIN can be found in the <VF INDICATOR3> screen on the VF page.
*2
If the remaining free space or memory capacity is 9999 min or more, [9999min] is displayed.
Information Item
Indication
Status
36.
B.GAMMA
RANGE
1
2
3
This indicates the level (upper limit) of the compression/expansion.
37.
Switch lock
setting
!SW LOCK
This is displayed when any of the side switches (GAIN, OUTPUT and AWB
switches) are operated with SIDE SW LOCK in a locked state. Note that it is
not displayed during when AJ-RC10G is connected and in operation.
38.
Exposure
Indication
–4
–3
±±
–3
±
–3
–2
±±
–2
±
–2
–1
±±
–1
±
–1
±0
+0
±
+0
±±
+1
+1
±
+1
±±
+2
+2
±
+2
±±
+3
+3
±
+3
±±
+4
+4
±
+4
±±
+5
When GAMMA MODE SEL has been set to “FILM-REC” and STATUS MODE
to “FILM REC”, executing the Y GET operation measures brightness in
proximity to the center marker. The measured value is displayed as an
exposure level.
A measured output signal of 30% is displayed as ±0 (normal). This value is
then adjusted by +1 STOP for every doubling of the amount of incident light
and by –1 STOP for every halving of the amount incident light. Each
±
represents 1/3 STOP.
GAMMA MODE SEL is set from the <GAMMA> screen of the PAINT page.
STATUS MODE is set from the <VF DISPLAY> screen of the VF page.
P2 Card Remaining Free Space/capacity Indication
Status of unit
Recording
status
Menu option
P2CARD REMAIN*
1
5. P2 card remaining free space
indication*
2
6. P2 card remaining free space
indication (during MODE CHECK)*
2
Under normal
conditions
Other than
LOOP REC
mode
TOTAL
The total remaining free space of all P2
cards loaded in the P2 card slots is
indicated in minutes.
Example: 30min
Not provided
ONE-CARD
The number of the P2 card slot holding the
target P2 card, together with that card’s
remaining free space indicated in minutes.
Example:
8min
Not provided
OFF
Not provided
Not provided
LOOP REC
mode
TOTAL/ONE-CARD
Indicated as “LOOP”
Not provided
OFF
Not provided
Not provided
During MODE
CHECK
Other than
LOOP REC
mode
TOTAL/ONE-CARD/
OFF
The total remaining free space and
capacities of all P2 cards loaded in the P2
card slots are indicated in minutes.
Example: 20/40
The number of the P2 card slot
holding the target P2 card, together
with that card’s remaining free space,
indicated in minutes.
Example:
8min
LOOP REC
mode
Indicated as “LOOP”
The estimated recording time is
indicated in minutes.
Example: 7min