LAN, Max. voltage: 24 V, Tally LED, Max. current: 50 mA, TALLY/GPI 1, Pin No., Signal name
View all Panasonic AV-UHS500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 144 highlights
External interfaces Example of GPI Out and ALARM connections Ensure that the conditions given below are satisfied. Dielectric strength: Max. DC 24 V Current: Max. 50 mA AV-UHS500 (Max. voltage: 24 V) GPI Out ALARM Out (Max. current: 50 mA) Tally LED Com Example of GPI In connections Provide contact inputs. AV-UHS500 +3.3 V GPI In Com TALLY/GPI 1 87654321 15 14 13 12 11 10 9 Pin No. 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8 Signal name GPI-Out1 GPI-Out9 GPI-Out2 ALARM Out GPI-Out3 GPI-In1 GPI-Out4 GPI-In2 GPI-Out5 GPI-In3 GPI-Out6 GPI-In4 GPI-Out7 GPI-Com GPI-Out8 TALLY/GPI 2 87654321 15 14 13 12 11 10 9 Pin No. 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8 Signal name GPI-Out10 GPI-Out18 GPI-Out11 GPI-Out19 GPI-Out12 GPI-In5 GPI-Out13 GPI-In6 GPI-Out14 GPI-In7 GPI-Out15 GPI-In8 GPI-Out16 GPI-Com GPI-Out17 LAN Connect the unit and computer or the unit and an external device*. *: An external device can be controlled from the unit. pp Use a LAN cable (category 5e or above). 144