Panasonic AV-UHS500 4K Switcher Operating Instructions - Page 98

Setting the delay amount, Freezing the input signals, Setting freeze

Page 98 highlights

Input/output signal settings Setting the delay amount The input signals can be delayed. pp This setting is for input signals to 12G SDI IN5 to 8 and the optional SDI input unit (IN-A1 to 4 and IN-B1 to 4). 1 On the Input sub menu, use [F2] to select the input to be set using the Select item.  Refer to "Input signal settings". 2 Use [F1] to display the FS sub menu. 3 Use [F3] to set the delay amount using the Delay item. Freezing the input signals The input signals can be frozen and used. While signals are frozen, the tally signals of the corresponding input will not be output. Setting freeze 1 On the Input sub menu, use [F2] to select the input to be set using the Select item.  Refer to "Input signal settings". 2 Use [F1] to display the Freeze sub menu. Frame Field The images are frozen frame by frame. The images are frozen field by field. This is used to freeze moving images. With interlace signals, however, diagonal lines and moving parts appear jagged. Frame or Field can also be selected while an image is frozen. 3 Press the [F3] to freeze the input image or cancel the freeze. If the [F3] is pressed while the display is "Off", the video signal is frozen, and the display is set to "On". If the [F3] is pressed while the display is "On", the video signal freezing is canceled, and the display is set to "Off". The "F" mark appears in front of the name of the material when the signals set for output of multi view displays are frozen. ppWhen the unit is used with the frame synchronizer function OFF, the output images may be disturbed when freezing is executed, but the frozen images will not be adversely affected. ppIf, when the switcher is used with the frame synchronizer function at OFF, "On" is set as the freeze setting, the frame synchronizer function will be automatically switched to ON. 98

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188

98
Input/output signal settings
Setting the delay amount
The input signals can be delayed.
p
This setting is for input signals to 12G SDI IN5 to 8 and the
optional SDI input unit (IN-A1 to 4 and IN-B1 to 4).
1
On the Input sub menu, use [F2] to select the input to
be set using the Select item.
Refer to “Input signal settings”.
2
Use [F1] to display the FS sub menu.
3
Use [F3] to set the delay amount using the Delay item.
Freezing the input signals
The input signals can be frozen and used.
While signals are frozen, the tally signals of the corresponding
input will not be output.
Setting freeze
1
On the Input sub menu, use [F2] to select the input to
be set using the Select item.
Refer to “Input signal settings”.
2
Use [F1] to display the Freeze sub menu.
Frame
The images are frozen frame by frame.
Field
The images are frozen field by field.
This is used to freeze moving images.
With interlace signals, however, diagonal
lines and moving parts appear jagged.
Frame or Field can also be selected while an image is
frozen.
3
Press the [F3] to freeze the input image or cancel the
freeze.
If the [F3] is pressed while the display is “Off”, the video
signal is frozen, and the display is set to “On”.
If the [F3] is pressed while the display is “On”, the video
signal freezing is canceled, and the display is set to
“Off”.
The “F” mark appears in front of the name of the
material when the signals set for output of multi view
displays are frozen.
p
When the unit is used with the frame synchronizer
function OFF, the output images may be disturbed when
freezing is executed, but the frozen images will not be
adversely affected.
p
If, when the switcher is used with the frame synchronizer
function at OFF, “On” is set as the freeze setting, the
frame synchronizer function will be automatically
switched to ON.