Yamaha CLP-470 Owner's Manual - Page 58

Program Change ON/OFF, Initial Setup Send, The following data can be sent.

Page 58 highlights

Program Change ON/OFF 470 440 430 S408 S406 465GP 470 440 430 S408 S406 465GP Normally this instrument responds to MIDI program change numbers received from an external keyboard or other MIDI device, causing the correspondinglynumbered Voice to be selected on the corresponding channel (the keyboard Voice does not change). The instrument will normally also send a MIDI program change number whenever one of its Voices is selected, causing the correspondingly-numbered Voice or program to be selected on the external MIDI device if the device is set up to receive and respond to MIDI program change numbers. This function makes it possible to cancel program change number reception and transmission so that Voices can be selected on the instrument without affecting the external MIDI device. NOTE For information on program change numbers for each of the instrument's Voices, refer to the online manual "MIDI Data Format." Setting range: ON/OFF Default setting: ON Control Change ON/OFF 470 440 430 S408 S406 465GP 470 440 430 S408 S406 465GP Normally this instrument responds to MIDI control change data received from an external MIDI device or keyboard, causing the Voice on the corresponding channel to be affected by pedal and other "control" settings received from the controlling device (the keyboard Voice is not affected). The instrument also transmits MIDI control change information when the pedal or other appropriate controls are operated. This function makes it possible to cancel control change data reception and transmission so that, for example, the instrument's pedal and other controls can be operated without affecting an external MIDI device. NOTE For information on control change messages that can be used with this instrument, refer to the online manual "MIDI Data Format." Setting range: ON/OFF Default setting: ON Initial Setup Send 470 440 430 S408 S406 465GP 470 440 430 S408 S406 465GP This function lets you send the data of the panel settings to a computer. By transmitting the panel settings and recording them on the MIDI sequence recorder prior to the actual performance data, the instrument will be automatically restored to the same settings when the performance is played back. You can also use this function to change the settings of a connected tone generator to the same settings as the instrument. 1. Set up the panel controls as desired. 2. Connect the Clavinova to a sequencer via MIDI, and set up the sequencer so it can receive the setup data. 3. Call up the Function mode and select the function number. 4. Press the [+/YES] button to transmit the panel/ status data. will appear on the display when the data has been successfully transmitted. The following data can be sent. • Voice • [REVERB] type/depth • [EFFECT] type/depth • (CLP-470/440/S408/S406) Split point • Scale • Dual Balance • Dual Detune • (CLP-470/440/S408/S406) Split Balance • Damper Resonance Depth (CLP-470/440/S408/S406)/ (CLP-430/465GP) • Soft Pedal Effect Depth (CLP-470/440/S408/S406)/ (CLP-430/465GP) • (CLP-470/440/S408/S406) String Resonance Depth • (CLP-470/440/S408/S406) Sustain Sample Depth • (CLP-470/440/S408/S406) Keyoff Sample Volume 58 Detailed Settings Function Parameters - Various Convenient Settings

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

58
Detailed Settings
Function Parameters — Various Convenient Settings
Program Change ON/OFF
Normally this instrument responds to MIDI program
change numbers received from an external keyboard or
other MIDI device, causing the correspondingly-
numbered Voice to be selected on the corresponding
channel (the keyboard Voice does not change). The
instrument will normally also send a MIDI program
change number whenever one of its Voices is selected,
causing the correspondingly-numbered Voice or
program to be selected on the external MIDI device if the
device is set up to receive and respond to MIDI program
change numbers.
This function makes it possible to cancel program
change number reception and transmission so that
Voices can be selected on the instrument without
affecting the external MIDI device.
NOTE
For information on program change numbers for each of the
instrument’s Voices, refer to the online manual “MIDI Data Format.”
Setting range:
ON/OFF
Default setting:
ON
Control Change ON/OFF
Normally this instrument responds to MIDI control
change data received from an external MIDI device or
keyboard, causing the Voice on the corresponding
channel to be affected by pedal and other “control”
settings received from the controlling device (the
keyboard Voice is not affected).
The instrument also transmits MIDI control change
information when the pedal or other appropriate
controls are operated.
This function makes it possible to cancel control change
data reception and transmission so that, for example, the
instrument’s pedal and other controls can be operated
without affecting an external MIDI device.
NOTE
For information on control change messages that can be used with this
instrument, refer to the online manual “MIDI Data Format.”
Setting range:
ON/OFF
Default setting:
ON
Initial Setup Send
This function lets you send the data of the panel settings
to a computer. By transmitting the panel settings and
recording them on the MIDI sequence recorder prior to
the actual performance data, the instrument will be
automatically restored to the same settings when the
performance is played back. You can also use this
function to change the settings of a connected tone
generator to the same settings as the instrument.
1.
Set up the panel controls as desired.
2.
Connect the Clavinova to a sequencer via
MIDI, and set up the sequencer so it can receive
the setup data.
3.
Call up the Function mode and select the
function number.
4.
Press the [+/YES] button to transmit the panel/
status data.
will appear on the display when the data
has been successfully transmitted.
The following data can be sent.
• Voice
[REVERB] type/depth
[EFFECT] type/depth
• (CLP-470/440/S408/S406) Split point
• Scale
• Dual Balance
• Dual Detune
• (CLP-470/440/S408/S406) Split Balance
• Damper Resonance Depth
(CLP-470/440/S408/S406)/
(CLP-430/465GP)
Soft Pedal Effect Depth
(CLP-470/440/S408/S406)/
(CLP-430/465GP)
• (CLP-470/440/S408/S406) String Resonance Depth
• (CLP-470/440/S408/S406) Sustain Sample Depth
• (CLP-470/440/S408/S406) Keyoff Sample Volume
470
440
430
S408
S406
465GP
470
440
430
S408
S406
465GP
470
440
430
S408
S406
465GP
470
440
430
S408
S406
465GP
470
440
430
S408
S406
465GP
470
440
430
S408
S406
465GP