Brother International DCP-1400 Service Manual - Page 185
Specifications
View all Brother International DCP-1400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 185 highlights
WSW12 (Signal detection condition setting) Selector No. Function 1 Min. OFF time length of calling signal (Ci) 2 3 Max. OFF time length of calling signal (Ci) 4 5 Detecting time setting 6 7 Delay 8 Not used. Setting and Specifications No. 1 2 0 0 0 1 1 0 1 1 : 1500 ms : 500 ms : 700 ms : 900 ms No. 3 4 0 0 0 1 1 0 1 1 : 6 sec. : 7 sec. : 9 sec. : 11 sec. No. 5 6 0 0 0 1 1 0 1 1 : 800 ms : 200 ms : 250 ms : 150 ms 0: Yes 1: No • Selectors 1 through 4: Min. and max. OFF time length of calling signal (Ci) If the machine detects the OFF state of calling signal (Ci) for a time length which is greater than the value set by selectors 1 and 2 and less than the value set by selectors 3 and 4, it interprets the Ci signal as OFF. • Selectors 5 and 6: Detecting time setting These selectors set the time length required to make the machine acknowledge itself to be called. That is, if the machine continuously detects calling signals with the frequency set by selectors 1 through 4 of WSW14 during the time length set by these selectors 5 and 6, it acknowledges the call. • Selector 7: Delay Setting this selector to "0" allows the equipment to insert a 900 ms WAIT after acknowledgment of the call until the equipment turns on the CML relay to start receiving operation. 16