WSW24, setting, Selectors, length, start, pseudo, backtone, transmission, WSW25, through, Pause,
View all Brother International DCP-1400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 196 highlights
Selector No. 1 2 3 4 5 I 8 WSW24 (TAD setting 2) Function Not used. Time length from CML ON to start of pseudo ring backtone transmission Setting and Specifications No. 3 4 0 0 : 0 1 : 10 : 11 : 4 sec. 3 sec. 2 sec. 1 sec. Not used. • Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission These selectors set the length of time from CML-ON up to the start of pseudo ring backtone transmission. Selector No. 1 I 4 5 I 7 8 WSW25 (TAD setting 3) Function Setting and Specifications Not used. Pause between paging number and PIN Not used. No. 5 6 7 0 0 0 : 0 0 1 : 010 : 0 1 1 : 10 0 : 1 0 1 : 110 : 1 1 1 : 2 sec. 4 sec. 6 sec. 8 sec. 10 sec. 12 sec. 14 sec. 16 sec. • Selectors 5 through 7: Pause between paging number and PIN These selectors set the pause time between a telephone number being paged and PIN (private identification number) for the paging feature. 27