ATA Voice Field Reference Trunk Group page (SPA8000) B SIP GUID SIP Debug Option This field is not found in the PAP2T. The Global Unique ID is generated for each line for each device. When it is enabled, the ATA device adds a GUID header in the SIP request. The GUID is generated the first time the unit boots up and stays with the unit through rebooting and even factory reset. This feature was requested by Bell Canada (Nortel) to limit the registration of SIP accounts. The default is yes. SIP messages are received at or sent from the proxy listen port. This feature controls which SIP messages to log. Choices are as follows: • none-No logging. • 1-line-Logs the start-line only for all messages. • 1-line excl. OPT-Logs the start-line only for all messages except OPTIONS requests/responses. • 1-line excl. NTFY-Logs the start-line only for all messages except NOTIFY requests/responses. • 1-line excl. REG-Logs the start-line only for all messages except REGISTER requests/responses. • 1-line excl. OPT|NTFY|REG-Logs the start-line only for all messages except OPTIONS, NOTIFY, and REGISTER requests/responses. • full-Logs all SIP messages in full text. • full excl. OPT-Logs all SIP messages in full text except OPTIONS requests/responses. • full excl. NTFY-Logs all SIP messages in full text except NOTIFY requests/responses. • full excl. REG-Logs all SIP messages in full text except REGISTER requests/responses. • full excl. OPT|NTFY|REG-Logs all SIP messages in full text except for OPTIONS, NOTIFY, and REGISTER requests/ responses. The default is none. Cisco Small Business ATA Administration Guide 192

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239

ATA Voice Field Reference
Trunk Group page (SPA8000)
Cisco Small Business ATA Administration Guide
192
B
SIP GUID
This field is not found in the PAP2T.
The Global Unique ID is generated for each line for each
device. When it is enabled, the ATA device adds a GUID
header in the SIP request. The GUID is generated the first
time the unit boots up and stays with the unit through
rebooting and even factory reset. This feature was
requested by Bell Canada (Nortel) to limit the registration of
SIP accounts.
The default is
yes
.
SIP Debug Option
SIP messages are received at or sent from the proxy listen
port. This feature controls which SIP messages to log.
Choices are as follows:
none
—No logging.
1-line
—Logs the start-line only for all messages.
1-line excl. OPT
—Logs the start-line only for all messages
except OPTIONS requests/responses.
1-line excl. NTFY
—Logs the start-line only for all messages
except NOTIFY requests/responses.
1
-line excl. REG
—Logs the start-line only for all messages
except REGISTER requests/responses.
1-line excl. OPT|NTFY|REG
—Logs the start-line only for all
messages except OPTIONS, NOTIFY, and REGISTER
requests/responses.
full
—Logs all SIP messages in full text.
full excl. OPT
—Logs all SIP messages in full text except
OPTIONS requests/responses.
full excl. NTFY
—Logs all SIP messages in full text except
NOTIFY requests/responses.
full excl. REG
—Logs all SIP messages in full text except
REGISTER requests/responses.
full excl. OPT|NTFY|REG
—Logs all SIP messages in full text
except for OPTIONS, NOTIFY, and REGISTER requests/
responses.