Cisco SPA2102-SF Administration Guide - Page 219

Choose from {High, SynthesizedPoland, S.Africa, Less than 0.5ms, 256ms, 512ms, 5-16.5 Vrms

Page 219 highlights

ATA Voice Field Reference PSTN Line page (SPA3102) B Operational Loop Current Min On-Hook Speed Choices for mA are: {10, 12, 14, 16). The default is 10. Choose from {Less than 0.5ms, 3ms (ETSI), 26ms (Australia)}. The default is Less than 0.5ms. Current Limiting Enable Enable or disable current limiting. The default is no. Ring Frequency Min Minimum ring frequency to detect. The range is 5-100. Ring Frequency Max Ring Validation Time Ring Indication Delay Ring Timeout The default is 10. Maximum ring frequency to detect. The range is 5-100. The default is 100. Choose from {100, 150, 200, 256, 384, 512, 640, 1024} (ms). The default is 256ms. Choose from {0, 512, 768, 1024, 1280, 1536, 1792} (ms). The default is 512ms. Choose from {0, 128, 256, 384, 512, 640, 768, 896, 1024, 1152, 1280, 1408, 1536, 1664, 1792, 1920} (ms). Ring Threshold The default is 640 ms. Choose from {13.5-16.5, 19.35-2.65, 40.5-49.5} (Vrms). Ringer Impedance The default is 13.5-16.5 Vrms. Choose from {High, Synthesized(Poland, S.Africa, Slovenia)}. The default is high. Line-In-Use Voltage Determines the voltage threshold at which the SPA-3000 assumes the PSTN is in use by another handset sharing the same line (and will declare PSTN gateway service not available to incoming VoIP callers). The default value is 40v. Cisco Small Business ATA Administration Guide 219

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239

ATA Voice Field Reference
PSTN Line page (SPA3102)
Cisco Small Business ATA Administration Guide
219
B
Operational Loop
Current Min
Choices for mA are: {10, 12, 14, 16).
The default is
10
.
On-Hook Speed
Choose from {Less than 0.5ms, 3ms (ETSI), 26ms
(Australia)}.
The default is
Less than 0.5ms
.
Current Limiting
Enable
Enable or disable current limiting.
The default is
no
.
Ring Frequency Min
Minimum ring frequency to detect. The range is 5-100.
The default is
10
.
Ring Frequency
Max
Maximum ring frequency to detect. The range is 5-100.
The default is
100
.
Ring Validation
Time
Choose from {100, 150, 200, 256, 384, 512, 640, 1024} (ms).
The default is
256ms
.
Ring Indication
Delay
Choose from {0, 512, 768, 1024, 1280, 1536, 1792} (ms).
The default is
512ms
.
Ring Timeout
Choose from {0, 128, 256, 384, 512, 640, 768, 896, 1024,
1152, 1280, 1408, 1536, 1664, 1792, 1920} (ms).
The default is
640 ms
.
Ring Threshold
Choose from {13.5–16.5, 19.35–2.65, 40.5–49.5} (Vrms).
The default is
13.5-16.5 Vrms
.
Ringer Impedance
Choose from {High, Synthesized(Poland, S.Africa,
Slovenia)}.
The default is
high
.
Line-In-Use Voltage
Determines the voltage threshold at which the SPA-3000
assumes the PSTN is in use by another handset sharing the
same line (and will declare PSTN gateway service not
available to incoming VoIP callers).
The default value is
40v
.