Compaq Armada 6500 Compaq Storage Hub 12 Management Utilities Hardware and Sof - Page 37
Loop Up Wait Time msec, to be increased.
View all Compaq Armada 6500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
2-14 Compaq Storage Hub 12 Management Utilities Hardware and Software User Guide Figure 2-10. Diagnostic Tools configuration tab Loop Up Wait Time (msec) This parameter is the period of time both diagnostics must wait while the network is initializing. During this process, the network is expected to complete initializing. If the loop takes too long, the diagnostics will assume there is a problem and notification is triggered. Since some networks are larger than others, this could be as long as several seconds, so if there is a large percentage of false initialization problem indications, the parameters may need to be increased. Over-increasing this parameter will slow the actions of the diagnostics. The longer the Loop Up Wait Time is set, the longer it will take the diagnostics to work their way through their actions.