Compaq Armada 6500 Compaq Storage Hub 12 Management Utilities Hardware and Sof - Page 96
Table D-1, Error Messages, Message, Description, Action, Diagnostic in Progress, reserved
View all Compaq Armada 6500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
Troubleshooting the Management Module D-3 Message 0000 /* No errors */ 0001 /* Diagnostic in Progress */ 0002 /* reserved */ 0004 /* reserved */ 0008 /* Watchdog Timer Pop */ 0010 /* RAM Test */ 1 0020 /* Flash Test */ 1 0040 /* Serial EEPROM Test */ 0080 /* Reserved */ 0100 /* Voltage Limit Test */ Table D-1 Error Messages Description Information only. information only information only Processor Error Memory Fault Memory Fault Memory Fault The measurement of voltage to the power supplies has not met specification. Action None none none none Call Customer Service Call Customer Service Call Customer Service Call Customer Service None Corrective action: Verify AC input voltage level. Power hub off and then on. If message persists, and AC input power level is within specification, call Customer Service. 0200 /* Fan Start Test */ One or more fans have failed. Corrective action: Call Customer Service. continued 1 These are errors only if the console screen stops and goes no further.