Compaq Armada 6500 Compaq Storage Hub 12 Management Utilities Hardware and Sof - Page 95
Use Compaq Storage Hub 12 Management Utilities HMU to check, a 4-digit number
View all Compaq Armada 6500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 95 highlights
D-2 Compaq Storage Hub 12 Management Utilities Hardware and Software User Guide Inspect the hub fault LED indicators for apparent problems. See the next section. If the Fault LED goes on, the fans or the hub may be faulty or the temperature may be out of limits. Check that the GBICs are properly inserted. Check the port status LEDs. Verify GBICs by testing with a loopback connector to determine if the problem is with the cable or with the port. Use Compaq Storage Hub 12 Management Utilities (HMU) to check bypass status. Figure D-1 is an illustration showing LED status indicators. Figure D-1. Reading The HMM LEDs Error Messages The following error messages may display on the terminal console attached to the hub. They will be generated by the hub self-tests and would display immediately following the tests. The syntax is nnnn /* xxxxxx */ where nnnn = a 4-digit number and xxxxxx is a text string. Some are just informational while others may indicate a problem that should be checked. The section below lists them in numerical order. In most cases, they are accompanied by a brief explanation of the message followed by suggested action.