Compaq Armada 6500 Compaq Storage Hub 12 Management Utilities Hardware and Sof - Page 38
Loop Initialization Diagnostic
View all Compaq Armada 6500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Managing from Hub 12 Management Utilities GUI Menu Screen 2-15 Loop Initialization Diagnostic The Loop Initialization Diagnostic is activated whenever a loop cannot initialize properly. Loop initialization is initiated by a LIP and is properly completed with a CLS. The Loop Initialization Diagnostic can be modified to detect improper loop initialization through the Network Configuration tab. This can be accomplished by using one of the two criteria listed. Once active, the Diagnostic goes though a step-by-step process to determine which devices are the cause of improper loop initialization. Once the diagnostic has determined the culprit, it will then disable the device port involved, permitting the problem to be repaired. Figure 2-11. Loop Initialization Diagnostic screen There are two independent criteria that will trigger the Loop Initialization Diagnostic when limits are exceeded. One is Loop Down Duration. The other criterion is Initialization Frequency, which has three separate sub-parameters. Loop Down Duration is the number of consecutive seconds that the loop is unable to initialize before the Loop Initialization Diagnostic is triggered. If a LIP is detected and a CLS is not detected within the specified Loop Down Duration period, the Loop Initialization Diagnostic will be spawned.