Fluke 125 Fluke 125 Users Manual - Page 102

Cursor readout, Advanced Meter Functions

Page 102 highlights

Fluke 125 Users Manual Advanced Meter Functions Zero Set Set actual value to reference Fast/Normal/Smooth Meter settling time Fast: 1s @ 1 μs to 10 ms/div. Meter settling time Normal: 2s @ 1 μs to 10 ms/div. Meter settling time Smooth: 10s @ 1 μs to 10 ms/div. Touch Hold (on A) Captures and freezes a stable measurement result. Beeps when stable. Touch Hold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals. TrendPlot Graphs meter readings of the Min and Max values from 15 s/div (120 seconds) to 2 days/div (16 days) with time and date stamp. Automatic vertical scaling and time compression. Displays the actual and Minimum, Maximum, or average (AVG) reading. Fixed Decimal Point Possible by using attenuation keys. Cursor readout Sources: A, B Single Vertical Line: Average, Min and Max Readout Average, Min, Max and Time from Start of Readout (in ROLL mode; instrument in HOLD) Min, Max and Time from Start of Readout (in TRENDPLOT mode; instrument in HOLD) Dual Vertical Lines: Peak-Peak, Time Distance and Reciprocal Time Distance Readout Average, Min, Max and Time Distance Readout (in ROLL mode; instrument in HOLD) Dual Horizontal Lines: High, Low and Peak-Peak Readout Rise or Fall Time: Transition Time, 0%-Level and 100%-Level Readout (Manual or Auto Leveling; Auto Leveling only possible in Single Channel Mode) Accuracy: As Oscilloscope Accuracy 10-8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113

Fluke 125
Users Manual
10-8
Advanced Meter Functions
Zero Set
Set actual value to reference
Fast/Normal/Smooth
Meter settling time Fast:
1s @ 1
μ
s to 10 ms/div.
Meter settling time Normal: 2s @ 1
μ
s to 10 ms/div.
Meter settling time Smooth: 10s @ 1
μ
s to 10 ms/div.
Touch Hold (on A)
Captures and freezes a stable measurement result.
Beeps when stable. Touch Hold works on the main
meter reading, with thresholds of 1 Vpp for AC signals
and 100 mV for DC signals.
TrendPlot
Graphs meter readings of the Min and Max values from
15 s/div (120 seconds) to 2 days/div (16 days) with time
and date stamp. Automatic vertical scaling and time
compression.
Displays the actual and Minimum, Maximum, or average
(AVG) reading.
Fixed Decimal Point
Possible by using attenuation keys.
Cursor readout
Sources:
A, B
Single Vertical Line:
Average, Min and Max Readout
Average, Min, Max and Time from Start of Readout (in
ROLL mode; instrument in HOLD)
Min, Max and Time from Start of Readout (in
TRENDPLOT mode; instrument in HOLD)
Dual Vertical Lines:
Peak-Peak, Time Distance and Reciprocal Time
Distance Readout
Average, Min, Max and Time Distance Readout (in
ROLL mode; instrument in HOLD)
Dual Horizontal Lines:
High, Low and Peak-Peak Readout
Rise or Fall Time:
Transition Time, 0%-Level and 100%-Level Readout
(Manual or Auto Leveling; Auto Leveling only possible in
Single Channel Mode)
Accuracy:
As Oscilloscope Accuracy