Fluke 125 Fluke 125 Users Manual - Page 50

Performing Harmonics Measurements, Input Connections for Harmonics

Page 50 highlights

Fluke 125 Users Manual Performing Harmonics Measurements To perform harmonics measurements do the following: c Connect the inputs as indicated in figure 3-1 Connect input A for VOLT and for WATT, connect input B for AMP and for WATT. 10 mV/A - 1 mV/A BB120 Figure 3-1. Input Connections for Harmonics d Open the application mode menu. e Highlight HARMONICS f Accept your choice. You will see a screen like figure 3-2 If input A was already set to V, and input B was already set to AMP, the actual probe settings will be used. If not, a PROBE menu will be shown to enable you to select the appropriate probe setting. To change the probe settings if the PROBE menu is not automatically opened see Measurement Probes & Settings in chapter 1 . 3-2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113

Fluke 125
Users Manual
3-2
Performing Harmonics Measurements
To perform harmonics measurements do the following:
Connect the inputs as indicated in figure 3-1
Connect input A for VOLT and for WATT,
connect input B for AMP and for WATT.
BB120
10 mV/A -
1 mV/A
Figure 3-1. Input Connections for Harmonics
Open the application mode menu.
Highlight HARMONICS
Accept your choice. You will see a
screen like figure 3-2
If input A was already set to V, and input B was already set
to AMP, the actual probe settings will be used.
If not, a
PROBE menu will be shown to enable you to select the
appropriate probe setting.
To change the probe settings if the PROBE menu is not
automatically opened see Measurement Probes & Settings
in chapter 1 .