Fluke 125 Fluke 125 Users Manual - Page 96
Dual Input Oscilloscope, Vertical
View all Fluke 125 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
Fluke 125 Users Manual Dual Input Oscilloscope Vertical Frequency Response DC Coupled: excluding probes and test leads (via BB120 DC to 40 MHz (-3 dB) with STL120 1:1 shielded test leads DC to 12.5 MHz (-3 dB) DC to 20 MHz (-6 dB) with VP40 10:1 probe DC to 40 MHz (-3 dB) AC Coupled (LF roll off): excluding probes and test leads 10 Hz (-3 dB) with STL120 10 Hz (-3 dB) with 10 MΩ 10:1 Probe 1 Hz (-3 dB) Rise Time excluding probes, test leads 8.75 ns Input Impedance excluding probes and test leads 1 MΩ//12 pF with BB120 1 MΩ//20 pF with STL120 1 MΩ//225 pF with VP40 10:1 Probe 5 MΩ//15.5 pF Sensitivity 5 mV to 500 V/div Display Modes A, -A, B, -B Max. Input Voltage A and B direct, with test leads, or with VP40 Probe ..... 600 Vrms with BB120 300 Vrms (For detailed specifications, see "Safety", Figs. 4-1/4-2) Max. Floating Voltage from any terminal to ground 600 Vrms up to 400 Hz Resolution 8 bit Vertical Accuracy 1% + 0.05 range/div) Max. Vertical Move 4 divisions 10-2