HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 - (English) Advanc - Page 219
Step 8. Bind LUNs, Step 9. Add Global Hot Spares Optional
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 219 highlights
Installation settings on the host to ensure valid time stamps. This ensures that any information created by the disk array such as log entries reflect the proper time they occurred. To set the controller date and time, type: ammgr -t Step 8. Bind LUNs If a LUN structure has been created on the disk array either at the factory (A5277AZ) or by a reseller, it may not be necessary to perform this step. If no LUN structure has been created, only LUN 0 will exist. When performing this step, consult with the customer to ensure that the desired LUN configuration is created on the disk array. To bind a LUN, type: amcfg -L : -d ,,..... -r For example, the following command creates LUN 1 as RAID 5 using six disks: amcfg -L A:1 -d 1:1,2:10,3:10,4:1,5:1,6:1 -r 5 • For more information, see "Binding a LUN" on page 289 • To use SAM, see "Binding a LUN" on page 267 Step 9. Add Global Hot Spares (Optional) Hot spares provide an additional level of data protection. A hot spare automatically replaces a failed disk, restoring redundancy and protecting against a second disk failure. For maximum protection against disk failure, it is recommended that one hot spare be created per channel. To add a global hot spare, type: ammgr -h channel:ID For example, the following command creates a global hot spare: ammgr -h 4:3 Configuring the Disk Array 219