HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 - (English) Advanc - Page 334
The Uninterruptible Power Source has indicated that AC power
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 334 highlights
Table 44 SCSI Sense Codes (cont'd) Additional Sense Code 3F 3F 3F Additional Sense Code Qualifier BD C3 C7 Interpretation The controller has detected a drive with Mode Select parameters that are not recommended or which could not be changed. Currently this indicates the QErr bit is set incorrectly on the drive specified in the FRU field of the Request Sense data. The controller had detected a failed drive side channel specified in the FRU Qualifier field. Non-media Component Failure 3F C8 The controller has detected the failure of a subsystem component other than a disk or controller. The FRU codes and qualifiers indicate the faulty component. AC Power Fail 3F C9 The Uninterruptible Power Source has indicated that AC power is no longer present and the UPS has switched to standby power. Standby Power Depletion Imminent 3F CA The UPS has indicated that its standby power source is nearing depletion. The host should take actions to stop IO activity to the controller. Standby Power Source Not at Full Capability 3F CB The UPS has indicated that its standby power source is not at full capacity. AC Power Has Been Restored The UPS has indicated that AC power is now being used to supply power to the controller. 334 Status Conditions and Sense Code Information