HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 - (English) Advanc - Page 54
data on the LUN becomes inaccessible.
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
more disks. For highest availability, the disks in a RAID 3 LUN must be in different enclosures. If a disk fails or becomes inaccessible, the disk array can dynamically reconstruct all user data from the data and parity information on the remaining disks. When a failed disk is replaced, the disk array automatically rebuilds the contents of the failed disk on the new disk. The rebuilt LUN contains an exact replica of the information it would have contained had the disk not failed. Until a failed disk is replaced (or a rebuild on a global hot spare is completed), the LUN operates in degraded mode. The LUN must now use the data and parity on the remaining disks to recreate the content of the failed disk, which reduces performance. In addition, while in degraded mode, the LUN is susceptible to the failure of the second disk. If a second disk in the LUN fails while in degraded mode, parity can no longer be used and all data on the LUN becomes inaccessible. Figure 21 illustrates the distribution of user and parity data in a five-disk RAID 3 LUN. The the stripe segment size is 8 blocks, and the stripe size is 40 blocks (8 blocks times 5 disks). The disk block addresses in the stripe proceed sequentially from the first disk to the second, third, and fourth, then back to the first, and so on. Figure 21 RAID 3 LUN 54 Disk Array High Availability Features