HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 - (English) Advanc - Page 336
Diagnostic Self Test failed drive Read/ Write data turn
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 336 highlights
Table 44 SCSI Sense Codes (cont'd) Additional Sense Code 40 Additional Sense Code Qualifier NN Interpretation Diagnostic Failure on Component NN (0x80 - 0xFF) The controller has detected the failure of an internal controller component. This failure may have been detected during operation as well as during an on-board diagnostic routine. The values of NN supported in this release of the software are listed below. 43 00 80 - Processor RAM 81 - RAID Buffer 82 - NVSRAM 83 - RAID Parity Assist (RPA) chip or cache holdup battery 84 - Battery Backed NVSRAM or Clock Failure 91 - Diagnostic Self Test failed non-data transfer components test 92 - Diagnostic SelfTest failed data transfer components test 93 - Diagnostic SelfTest failed drive Read/ Write Buffer data turnaround test 94 - Diagnostic Self Test failed drive Inquiry access test 95 - Diagnostic Self Test failed drive Read/ Write data turnaround test 96 - Diagnostic Self Test failed drive Self Test Message Error The controller attempted to send a message to the host, but the host responded with a Reject message. 336 Status Conditions and Sense Code Information