HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 - (English) Advanc - Page 312
Resetting Battery Age, Installing Updated Patches, amutil -p, ammgr -b <ArrayID>, HP-UX 10.20
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 312 highlights
To purge the oldest log file in the host directory, type: amutil -p Note Always use the amutil -p command to purge the controller logs. This command maintains the catalog pointers used to access the log files. Using a system command such as rm to remove the log files will cause log catalog errors. Management of the log files can be automated by creating a script that purges the oldest log files at regular intervals using amutil -p. This technique can be used to ensure that the log files don't grow to a size that may cause the ?var file system to overflow. Resetting Battery Age The battery age should be reset to zero when the battery is replaced. This ensures an accurate indication of the age of the battery To reset the battery age to zero, type: ammgr -b Installing Updated Patches The following HP-UX patches are required when upgrading to HP08 firmware. The patches must be installed before upgraidng the contoller firmware to HP08. If the patches are not installed, the upgrade will fail. - HP-UX 10.20: PHCO_22627 and PHSS_22846 - HP-UX 11.0: PHCO_22628 and PHSS_22847 The required patches can be downloaded from the following web sites: http://us-support2.external.hp.com/index.html/ (External web site) ftp://hpatlse.atl.hp.com/hp-ux_patches/ (Internal web site) 312 Managing the Disk Array Using Array Manager 60