HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 - (English) Advanc - Page 366
Power-Up Troubleshooting, No Fault LEDs are on. See
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 366 highlights
Power-Up Troubleshooting When the disk array is powered up, each component perform an internal self-test, to ensure it is operating properly. Visual indications of power-up are: • The green Power LED on the controller enclosure is on • The green Power LED on each disk enclosures is on • All fans are operating • No Fault LEDs are on. See Figure 92 on page 368 and Figure 93 on page 377. The following LEDs will also be on: • Controller enclosure: - The green Full Charge LEDs on the controller batteries, if the batteries are fully charged. If the batteries are not fully charged, the Full Charge LEDs will flash until charging is complete, and then remain on. - The Power LEDs on the controller enclosure • Disk enclosure - The green Power Supply LEDs - Fan LEDs If the power-up sequence fails, the appropriate amber Fault LED will be on, identifying the failing component. If the power-up tests fail, all modules in the disk array must be examined for Fault LEDs that are on. See Table 48 on page 369 and Table 50 on page 377). Note Inserting a module while the power-up tests are running can cause the tests to fail. Insert all modules and then cycle power to rerun the power-up tests. 366 Power-Up Troubleshooting