Interpreting Component Status Values (HP-UX Only), Troubleshooting, Component/Status, Disks, Fans
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 379 highlights
Troubleshooting Note It is normal for the amber Fault LED on a component to go on briefly when the component initially starts up. However, if the Fault LED remains on for more than a few seconds, a fault has been detected. Interpreting Component Status Values (HP-UX Only) Common status terms have specific indications for various disk enclosure components. The component status condition terminology used by Array Manager 60 (AM60) may differ from that used by STM. Both terms are identified in Table 51. Table 51 Status Indications by Component Component/Status Disks BCCs Fans, Power Supplies Sensors AM60: Good STM: Optimal AM60: Critical STM: Fault - 2 Component is installed and no error conditions are known. N/A Hardware has failed. Voltage/temperature exceeds critical limit. AM60: Non-critical STM: Fault - 3 AM60: Not Installed STM: Not Present AM60: Unknown STM: Fault - 0 N/A BCC A and B N/A have different firmware versions. Component is not installed. N/A N/A N/A Voltage/temperature exceeds warning limit. Sensor has failed or status is not available. Not Available Component is installed without known errors, but has not been turned on or set into operation; or the controller that owns reporting has failed. SureStore E Disk System SC10 Troubleshooting 379