HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 - (English) Advanc - Page 342
Write Back Caching Could Not Be Enabled - RDAC Cache Size
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 342 highlights
Table 44 SCSI Sense Codes (cont'd) Additional Sense Code 95 Additional Sense Code Qualifier 02 Interpretation Controller Removal/Replacement Detected or Alternate Controller Released from Reset 98 01 98 02 98 03 A0 00 The controller detected the activation of the signal/signals used to indicate that the alternate controller has been removed or replaced. The controller has determined that there are multiple sub-enclosures with the same ID value selected. Sub-enclosure with redundant ESMs specifying different Tray levels. Sub-enclosure ESMs have different firmware levels Write Back Caching Could Not Be Enabled A1 00 The controller could not perform write back caching due to a battery failure or discharge, Two Minute Warning signal from the UPS, or an ICON failure. Write Back Caching Could Not Be Enabled - RDAC Cache Size Mismatch A4 00 The controller could not perform write back caching due to the cache sizes of the two controllers in the RDAC pair not matching. Global Hot Spare Size Insufficient for All Drives in Subsystem. A defined Global Hot Spare is not large enough to cover all of the drives present in the subsystem. Failure of a drive larger than the Global Hot Spare will not be covered by the Global Hot Spare drive. 342 Status Conditions and Sense Code Information