HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 - (English) Advanc - Page 329
Miscorrected Data Error - Due to Failed Drive Read, Recovered Data - Data Auto Reallocated
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 329 highlights
Table 44 SCSI Sense Codes (cont'd) Additional Sense Code 11 Additional Sense Code Qualifier 00 Interpretation Unrecovered Read Error 11 8A An unrecovered read operation to a drive occurred and the controller has no redundancy to recover the error (RAID 0, degraded RAID 1, degraded mode RAID 3, or degraded RAID 5). Miscorrected Data Error - Due to Failed Drive Read 18 02 A media error has occurred on a read operation during a reconfiguration operation, User data for the LBA indicated has been lost. Recovered Data - Data Auto Reallocated 1A 00 20 00 The controller recovered a read operation to a drive and no further action is required by the host. Auto reallocation may not have been used, but this is the only standard ASC/ ASCQ that tells the initiator that no further actions are required by the driver. Parameter List Length Error A command was received by the controller that contained a parameter list and the list length in the CDB was less than the length necessary to transfer the data for the command. Invalid Command Operation Code The controller received a command from the initiator that it does not support. Managing the Disk Array on HP-UX Status Conditions and Sense Code Information 329