Sample Log Entries, Command Example, amlog -s 05150000 -t mel -c rack_1
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 310 highlights
actual ArrayID must be used here. An alias cannot be used because alias names are not recorded in the log file. Command Example The following example displays the major event log entries for disk array rack_1. The log entries displayed are limited to only critical entries, and entries made after 0900 on 15 May 2000. amlog -s 05150000 -t mel -c rack_1 Sample Log Entries The following is a sample of a major event log entry. Major event log for Subsystem 001100A0B8060166 at Wed Nov 29 17:38:27 2000 Sequence Number = 14 Time Stamp = Wed Nov 29 17:38:19 2000 Event Type = Global Hot Spare Not Large Enough (224F) Event Category = Notification Component Type = Disk Enclosure = 5 Slot (0-based) = 3 Event Priority = Informational The following is a sample of an Asynchronous Event Log entry: Controller log sense for Subsystem 001100A0B8060166 at Mon Dec 4 12:51:34 2000 Controller Time Stamp = 032307 083318 FRU Code = 0x08 FRU Code Qualifier = 0x8142 Sense Key = 0x06 Additional Sense Code = 0x3F Add Sense Code Qual = 0xC7 Decoded Field Replaceable Unit Information: FRU Group = Sub-Enclosure Group FRU ID Setting = 1 FRU Type = Power Supply 310 Managing the Disk Array Using Array Manager 60