Dell PowerEdge M420 Hardware Owner's Manual - Page 118
Integrated, Devices, the System Setup Program
View all Dell PowerEdge M420 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
Table 1-26. Blade Messages (continued) Message Causes Corrective Actions Memory tests terminated by keystroke. The spacebar or ESC key was pressed during POST to terminate the memory test. Information only. Keyboard data line failure. Keyboard stuck key failure. Keyboard cable connector Ensure that the keyboard is loose or improperly properly connected. If the connected. Keyboard or problem persists, see keyboard/mouse controller "Getting Help" on page 337. may be faulty. Keyboard fuse has Overcurrent detected in See "Getting Help" on failed. the keyboard connector. page 337. No boot device available. Faulty or missing diskette Check the Integrated drive, optical drive, or hard Devices configuration drive. settings in the System Setup program and ensure that the controller for the boot device is enabled. See "Using the System Setup Program and UEFI Boot Manager" on page 127. Ensure that the controller for the boot device is enabled. If the problem persists, replace the drive. See "Hard Drives" on page 247. No boot sector on hard-disk drive. An operating system is not Check the hard-drive on the hard drive. configuration settings in the System Setup program. See "Using the System Setup Program and UEFI Boot Manager" on page 127. No timer tick interrupt. Faulty blade board. See "Getting Help" on page 337. Not a boot diskette. Not a bootable diskette. Use a bootable diskette. 118 About Your System