Dell PowerEdge MX740c EMC PowerEdge MX740c Installation and Service Manual - Page 87
iDRAC card, Removing the iDRAC card
![]() |
View all Dell PowerEdge MX740c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
If the PHM slips off the blue retention clips when the screws are partially tightened, follow these steps to secure the PHM: a. Loosen both the heat sink screws completely. b. Lower the PHM on to the blue retention clips, following the procedure described in step 2. c. Secure the PHM to the system board, following the replacement instructions listed in step 3 above. NOTE: The processor and heat sink module retention screws should not be tightened to more than 0.11 kgf-m (1.13 N.m or 10+/-0.2 in-lbf). Figure 57. Installing a processor and heat sink module Next steps 1. Install the air shroud. 2. Follow the procedure listed in After working inside your sled. iDRAC card In the PowerEdge MX740c, iDRAC is not embedded on the system board. The iDRAC is a separate card unlike other 14G PowerEdge servers. The vFlash card for the PowerEdge MX740c is available on the iDRAC card. Removing the iDRAC card Prerequisites 1. Follow the safety guidelines listed in Safety Instructions. 2. Follow the procedure listed in Before working inside the sled. 3. Remove the air shroud. CAUTION: If either the system board or iDRAC card fails, it is required to replace both system board and iDRAC card at the same time. Steps Hold the blue pull tag and lift the iDRAC card away from the system. Installing and removing system components 87