Dell PowerEdge R760XA Installation and Service Manual - Page 29
Liquid cooling restrictions, Thermal restriction matrix, ASHRAE A4 environment
View all Dell PowerEdge R760XA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
ASHRAE A4 environment ● Processors > 185 W are not supported ● GPUs at rear slots are not supported ● Nvidia A2 GPU is supported at front slots. Other GPUs are not supported ● 128 GB or greater capacity RDIMMs are not supported ● 2.5-inch NVMe storages are not supported ● BOSS-N1 is not supported ● Two power supplies are required. System performance may be reduced in the event of a PSU failure ● Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported ● OCP cards 3.0 are not supported ● 85°C (185°F) active optics cable is required Liquid cooling restrictions ASHRAE A2 environment ● GPU > 400 W are not supported ASHRAE A3 environment ● GPU at rear slots are not supported ● Nvidia A2 GPU is supported at front slots. Other GPUs are not supported ● 128 GB or greater capacity RDIMMs are not supported ● Two power supplies are required. System performance may be reduced in the event of a PSU failure ● Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported ● 85°C (185°F) active optics cable is required ASHRAE A4 environment ● GPU at rear slots are not supported ● Nvidia A2 GPU is supported at front slots. Other GPUs are not supported ● 128 GB or greater capacity RDIMMs are not supported ● 2.5 inch NVMe storage are not supported ● BOSS-N1 is not supported ● Two power supplies are required. System performance may be reduced in the event of a PSU failure ● Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported ● OCP cards 3.0 are not supported ● 85°C (185°F) active optics cable is required Thermal restriction matrix Table 27. References used in the restriction table. Label STD HSK LP FH Description Standard Heat sink Low Profile Full Height Technical specifications 29