Removing the CR Unit 4
![]() |
UPC - 010343859043
View all Epson R260 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 105 highlights
EPSON Stylus Photo R260/R265/R270, R360/R380/R390 3. Disengage the end of the Spring (2) from the hook, and the other end from the slit of the CR shaft, and remove the Spring (2). 4. Remove the washer, and remove the Right PG Cam. CR Shaft Spring (2) 6. Remove the CR Shaft from the CR Unit. CR Shaft Revision B CR Unit Washer Removal Direction Right PG Cam Hook Figure 4-146. Removing the CR Unit (2) 5. Hold the CR Unit from the bottom and lift up the CR Shaft, release from the bushing in the (1) (2) order, and remove the CR Unit with the Shaft from the Main Frame. 1 CR Unit CR Shaft 2 Bushing Bushing Figure 4-147. Removing the CR Unit (3) Figure 4-148. Removing the CR Unit (4) 7. Remove the Timing Belt from the CR Unit. CR Unit Timing Belt Figure 4-149. Removing the CR Unit (5) 8. Disconnect the FFC from the CR Encoder connector, pull out the FFC from the slit of the CR Unit, and remove the Head FFC. Head FFC CR Unit Figure 4-150. Removing the CR Unit (6) Disassembly/Assembly Disassembly of the Printer Mechanism 106