Epson R260 Service Manual - Page 45
Encoder Board and the PW Sensor.
UPC - 010343859043
View all Epson R260 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
EPSON Stylus Photo R260/R265/R270, R360/R380/R390 Revision B Occurrence Timing Symptom Table 3-10. Troubleshooting for CDR Tray Error Failed Part Check Point 1. Is there any paper dust or ink stain on the PW Sensor? Cable Remedy 1. Clean off any dirt on the PW Sensor. Reference When printing on CDs/DVDs The CDR Tray center detection sequence is interrupted, and the tray is ejected. PW Sensor PW Senor Main Board 4.5.12 "CR Unit"(p.105) CR Encoder Board PW Sensor 2. Is the PW Sensor cable not connected to the CR Encoder Board and the PW Sensor? 3. Is the PW Sensor cable broken? 4. Is the PW Sensor damaged? 1. Is there any chipped or broken elements on the Main Board? 2. Connect the PW Sensor cable to the CR Encoder Board and the PW Sensor. 3. Replace the CR Unit. 4. Replace the CR Unit. 4.5.12 "CR Unit"(p.105) 1. Replace the Main Board. 4.3.2 "Removing the Main Board Unit"(p.78) Troubleshooting Troubleshooting by Error Message 46