EPSON Stylus Photo R260/R265/R270, R360/R380/R390 4.3.6 Middle Housing Parts/Components need to be removed in advance All exterior parts/components / Card Board (USB Board) / Main Board Unit Removal procedure CHECK P O IN T Refer to the Orientation Definition below for the directions indicated in the following procedures. •"4.1.6 Orientation Definition (p.61)" 1. Remove the two screws. • Screw : C.B.S. M3x10 (tightening torque: 5-7 kgf.cm) (The numbers shown in the figure indicate the order of tightening the screws.) Middle Housing Front Frame 2 1 Figure 4-79. Removing the Middle Housing (1) Revision B 2. Remove the Middle Housing taking extra care not to get the FFC caught on the opening part. Removal Direction Head FFC Opening Middle Housing Figure 4-80. Removing the Middle Housing (2) 3. Disengage the hook from the hole of the rib, and remove the Left Ground Plate MB. 4. Remove the Right Ground Plate MB. Left Ground Plate MB Removal Direction Right Ground Plate MB Disengage the hook Figure 4-81. Removing the Middle Housing (3) Tighten the screws in the order given in Fig.4-79. After installing the Middle Housing, check that the Left/Right Ground Plates MB are properly grounded. Disassembly/Assembly Removing Control Boards 86