HP 6125XLG R2306-HP 6125XLG Blade Switch FCoE Command Reference
HP 6125XLG Manual
View all HP 6125XLG manuals
Add to My Manuals
Save this manual to your list of manuals |
HP 6125XLG manual content summary:
- HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 1
HP 6125XLG Blade Switch FCoE Command Reference Part number: 5998-3741 Software version: Release 2306 Document version: 6W100-20130912 - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 2
, or use of this material. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 3
timer resource-allocation 31 fc wwn default-fc4-type 31 priority 33 timer distributed-services 33 timer error-detect 34 timer resource-allocation 35 wwn area-port-id 36 VSAN commands 36 display vsan port-member 36 port trunk vsan 37 vsan 38 FC routing commands 39 display fc exchange 39 - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 4
(zone-alias view 69 member (zoneset view 70 zone clone 71 zone default-zone permit 71 zone name 72 zone rename 72 zone-alias clone 73 zone 77 zoneset distribute full 78 zoneset name 78 zoneset rename 79 NPV commands 80 display npv login 80 display npv status 81 display npv traffic-map - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 5
Support and other resources 88 Contacting HP 88 Subscription service 88 Related information 88 Documents 88 Websites 88 Conventions 89 Index 91 iii - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 6
FCoE commands The switch supports FCoE only when operating in advanced mode. For more information about system operating modes, see Fundamentals Configuration Guide. FCoE mode commands fcoe-mode Use fcoe-mode to configure an FCoE mode for the switch. Use undo fcoe-mode to restore the default. Syntax - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 7
# Convert the switch operating in FCF mode to NPV mode. [Sysname] undo fcoe-mode All current FC configuration will be lost. Continue? [Y/N]:y [Sysname] fcoe-mode npv VFC interface and FIP commands bind interface Use bind interface to bind the VFC interface to a specified Ethernet interface. Use undo - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 8
then use their undo forms or follow the command reference to individually restore their default settings. If your restoration attempt still fails, follow the error message instructions to resolve the problem. Examples # Restore the default settings for interface VFC 1. system-view [Sysname - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 9
interface VFC 1. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] description Vfcport1 Related commands display interface vfc display fcoe Use display fcoe to display FCoE global configuration. Syntax display fcoe Views Any view Predefined user roles network-admin network-operator 4 - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 10
Examples # Display FCoE global configuration. display fcoe FCoE MAC : 0000-1234-0202 FC-MAP : 0efc25 FCF Priority: 128 FKA period : 8 seconds Table 1 Command output Field FCoE MAC FC-MAP FCF Priority FKA period Description FCoE MAC address of the switch. FC-MAP value. System FCF - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 11
the interface-number argument, this command displays information processing: disabled Link layer protocol is FC Port WWN is 20:64:00:a0:fc:00 . If the VFC interface is not configured with an IP address, this field interface bound to the VFC interface. FCoE MAC address bound to the VFC interface - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 12
type of the interface: • A-Access. • H-Hybrid. • T-Trunk. PVID Port VLAN ID (PVID). Description Interface description configured by using the description command. Without the description keyword, the display interface brief command displays a maximum of 27 characters of the description. With the - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 13
user roles network-admin Parameters e: Configures the VFC interface to operate in E mode. f: Configures the VFC interface to operate in F mode. np: Configures the VFC interface to operate in NP mode. Usage guidelines VFC interfaces support three modes: E, F (default), and NP. • When an FCF switch - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 14
] fcoe enable vsan 6 fcoe fcf-priority Use fcoe fcf-priority to configure the FCF priority for the VFC interface. Use undo fcoe fcf-priority to restore the default. Syntax fcoe fcf-priority priority undo fcoe fcf-priority Default The default setting is 128. Views VFC interface view Predefined user - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 15
] interface vfc 1 [Sysname-Vfc1] fcoe fcf-priority 12 fcoe fcmap Use fcoe fcmap to configure an FC-MAP value. Use undo fcoe fcmap to restore the default. Syntax fcoe fcmap fc-map undo fcoe fcmap Default The default setting is 0x0EFC00. Views System view Predefined user roles network-admin Parameters - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 16
-adv-period Use fcoe fka-adv-period to configure an FKA advertisement period value. Use undo fcoe fka-adv-period to restore the default. Syntax fcoe fka-adv-period fka-adv-period undo fcoe fka-adv-period Default The default setting is 8 seconds. Views System view Predefined user roles network-admin - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 17
vfc interface-number Default No VFC interface exists. Views System view Predefined user roles network-admin Parameters interface-number: Specifies a VFC interface by its number in the range of 1 to 1024. Usage guidelines A VFC interface is a logical interface manually created on the FCF switch to - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 18
[ number ] ] Views User view Predefined user roles network-admin Parameters number: VFC interface number. Usage guidelines Clear the existing statistics before collecting traffic statistics within a specific period of time on an interface. If you do not specify the vfc number option, this command - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 19
the allowed domain ID list. If the allowed domain ID list configured does not include any of the already assigned domain IDs or manually configured domain IDs, the configuration will fail. • Non-principal switch-The manually configured domain ID must be within the allowed domain ID list. Otherwise - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 20
the principal switch. If the runtime domain ID for a switch is beyond the new allowed domain ID list, the configuration will also fail. HP recommends that using this command includes runtime and configuration information of the local switch and runtime information of the principal switch. Examples - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 21
Downstream Interface Vfc1 Vfc2 Vfc3 Table 4 Command output Field State Switch WWN Fabric name Priority Domain ID Configuration information Domain configure Domain auto-reconfigure Fabric name Priority Domain ID Principal switch running time information Priority Path Interface Description - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 22
ID list of the VSAN. Total number of domains. WWN of the switch. Principal indicates a principal switch, and Local indicates a local switch. Related commands domain configure enable display fc ess Use display fc ess to display the Exchange Switch Support (ESS) negotiation result, including the - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 23
FC-4 Features name server objects: No Support receiving ACCept with 0 length: Yes Fabric Controller Capability: Support receiving the SW_RSCN Request: Yes Table 6 Command output Field Description Domain Domain ID of the switch. Directory Service Capability List of directory server capabilities - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 24
VSAN Entries 1 3 2 3 3 3 Total entries: 9 # Display the total number of logged-in nodes for VSAN 3. display fc login vsan 3 count Total entries: 3 Table 7 Command output Field Interface VSAN FCID Description Interface that connects the switch to the node. VSAN ID. FC address - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 25
WWN Total entries Total entries Description WWN of the port connecting the node to the switch. Total number of logged-in nodes. Total number of logged-in nodes. display fc name-service database Use display fc name-service database to display the name server database information. Syntax display - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 26
Description Port type registered by the node with the switch: • 0x00(Unidentified)-No port type supporting Initiator, Target, or Initiator/Target. # Display detailed information about the name service database. display fc name-service database verbose VSAN:1 FCID:0x030001 Port - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 27
--- Table 9 Command output Field FCID Type Port-WWN(vendor) Node-WWN Class Node-IP-addr FC4-types(FC4 features) Symbolic-port-name Symbolic-node-name Port-type Fabric-port-WWN Hard-addr Total entries Description FC address of the N_Port. Port type registered by the node with the switch: • 0x00 - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 28
(RSCNs) to receive: • fabric detected rscns-Receives all RSCNs sent by the switches in the fabric. • nx_port detected rscns-Receives all RSCN messages sent by N_Ports. • full detected rscns-Receives all RSCN messages. Number of SCR entries in the VSAN. display fc timer Use display fc timer to - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 29
information of the two fabrics is different and the domain ID lists are not empty or overlapping. • When the principal switch in a fabric is down, the system automatically performs a non-disruptive reconfiguration. This command is available only when the fabric configuration function is enabled. 24 - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 30
. Use undo domain configure enable to disable the fabric configuration function for the switch in a specified VSAN. Syntax domain configure enable undo domain configure enable Default The fabric configuration function is enabled in each VSAN. Views VSAN view Predefined user roles network-admin Usage - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 31
1 [Sysname-vsan1] domain restart disruptive The command may cause traffic interruption. Continue? [Y/N]:y Related commands domain configure enable domain-id Use domain-id to specify a domain ID for the switch in a specified VSAN. Use undo domain-id to restore the default. Syntax domain-id domain-id - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 32
a default value of 0, which cannot distinguish devices. Therefore, you must statically configure or dynamically assign domain IDs for FCF switches. HP recommends that you specify the same type of domain IDs for all switches in the same VSAN. Examples # Specify static-type domain ID 55 for the switch - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 33
:xx:xx:xx:xx, where x is a hexadecimal number. Usage guidelines An FCF switch supports assigning a fabric name to each VSAN, in the same format as the WWN (a 64-bit address). If the user does not configure a fabric name, the switch's WWN is used as the fabric name after FCoE is enabled. You need to - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 34
undo fc name-service auto-discovery Default Auto discovery of SCSI-FCP information is enabled. Views VSAN view Predefined user roles network-admin mdc-admin Usage guidelines In some cases, for example, when a node logs out and then logs in, the node does not register SCSI-FCP support and therefore - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 35
VSAN at the same time, the configuration for the VSAN is given priority. Examples # Set the global distributed service timeout period to 6000 milliseconds. system-view [Sysname] fc timer distributed-services 6000 Related commands timer distributed-services fc timer error-detect Use fc - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 36
-allocation Default The global resource allocation timeout period is 10000 milliseconds. Views System view Predefined user roles network -allocation 6000 Related commands timer resource-allocation fc wwn default-fc4-type Use fc wwn default-fc4-type to configure the default FC4 information for - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 37
in the name service database for that node. When a node registers FC4 information or the switch obtains the SCSI-FCP information, the switch replaces the default FC4 information with the registered FC4 information or obtained SCSI-FCP information. This command can be used to configure only one - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 38
different priorities in different VSANs. The priority configuration for the switch does not take effect until a disruptive reconfiguration is performed by using the domain restart disruptive command. Examples # Specify the priority as 64 for the switch in VSAN 1. system-view [Sysname] vsan - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 39
same time, the configuration for the VSAN is given priority. Examples # Set the distributed service timeout period to 6000 milliseconds for VSAN 1. system-view [Sysname] vsan 1 [Sysname-vsan1] timer distributed-services 6000 Related commands fc timer distributed-services timer error-detect - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 40
commands Default The resource allocation timeout period is 10000 milliseconds. Views VSAN view Predefined user roles network-admin Parameters value: Resource allocation timeout period in the range of 5000 to 10000 milliseconds. Usage guidelines The resource allocation timeout period can be configured - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 41
port-id Default No binding is configured. Views VSAN view Predefined user roles network-admin Parameters wwn-value: WWN of the N_Port, in the format of xx:xx:xx:xx:xx:xx:xx:xx, where x is a hexadecimal number. area-port -port-id ab12 VSAN commands display vsan port-member Use display vsan port-member - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 42
interfaces of all VSANs. display vsan port-member VSAN 1: Access Ports: Trunk Ports: VSAN 100: Access Ports: Trunk Ports: Vfc2 Figure 1 Command output Field Access Ports Description The switch does not support access ports. port trunk vsan Use port trunk vsan to assign the interface to - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 43
20 through 100. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] port trunk vsan 1 to 2 10 20 to 100 vsan Use vsan to create a VSAN vsan-id undo vsan vsan-id Default Only the default VSAN (VSAN 1) exists. Views System view Predefined user roles network-admin Parameters vsan vsan-id - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 44
number: Specifies an IRF member device number. If no IRF member device is specified, this command displays exchange entries for the master device. Usage guidelines The exchange is a basic concept of FC. All data frames and control frames Service classes that provide reliable transmission services - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 45
ESTABLISHED VSAN ID: 25 Table 11 Command output Field Local_ID:EXID/Local Remote_ID: is closed. ID of the IRF member device where the FC exchange is created. FC protocol number. FC exchange state flags: • be aged. FC connection service level (FC_CLASS_3 requires no ACK): • FC_CLASS_1. • - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 46
fcid [ mask-length ] ] vsan vsan-id Views Any view Predefined user roles network-admin network-operator Parameters fcid: Specifies a destination FC address in Table 12 Command output Field Destination count Interface Vfc1 Vfc2 Vfc3 InLoop0 InLoop0 InLoop0 InLoop0 Description Number of destination - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 47
Description Number of fcid [ mask | mask-length ] [ verbose ] Views Any view Predefined user roles network-admin network-operator Parameters vsan vsan-id: Specifies a VSAN by its 1 to 4095. If no VSAN is specified, this command displays routing information of all VSANs. fcid: Specifies the - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 48
display fc routing-table vsan 5 Destinations : 5 Routes : 8 Destination/mask Protocol Preference 0x040000/8 FSPF 20 0x040000/8 FSPF 20 0x040000/8 FSPF 20 0x040000/8 FSPF 20 0xfffc01/24 DIRECT 0 0xfffffa/24 DIRECT 0 0xfffffc/24 DIRECT 0 0xfffffd/24 DIRECT 0 Cost - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 49
Protocol: DIRECT Preference: 0 Cost: 0 Interface: InLoop0 State: Active Age: 0h21m36s Table 13 Command output Field VSAN Destination/mask Protocol Preference Cost Interface State Age Description VSAN number. FC address/mask. Protocol type: • DIRECT-Direct routes. • STATIC-Static routes. • FSPF- - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 50
-id ] Views Any view Predefined user roles network-admin network-operator Parameters Number of neighbors under helper : 0 Number of restarting neighbors : 0 FSPF graceful restart information of VSAN 2: Number of neighbors under helper : 0 Number of restarting neighbors : 0 Table 15 Command - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 51
user roles network-admin network-operator Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If no VSAN is specified, this command displays LSDB information for all VSANs. Usage guidelines Use this command to display FSPF LSDB information, including the total number - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 52
switch. FSPF Link State Database for Domain LSDB information for a specified domain ID (switch). LSR Type LSR type, which can only be Switch Link Record (0x01). LSR Incarnation number LSR instance number -id ] Views Any view Predefined user roles network-admin network-operator Parameters - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 53
-The local switch has sent Views Any view Predefined user roles network-admin network-operator command to display all FSPF statistics, consisting of global statistics and interface statistics. Global statistics consist of the current number of SPF calculations, number of error packets, total number - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 54
local switch. Number of SPF calculations. Number of error packets. Number of Number of LSUs and LSAs received in Init state. Packet type: Hello, LSU, or LSA. Number of packets received. Number of packets sent. Related commands reset fspf counters fc route-static Use fc route-static to configure - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 55
-number: Specifies the outgoing interface of the static FC route, which must be an existing VFC interface on the FCF switch. cost cost-value: Specifies the cost of the route, in the range of 0 to 65535 and defaulting to 0. Usage guidelines Static routes are routes that are manually configured - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 56
] interface vfc 1 [Sysname-Vfc1] fspf cost 1000 vsan 4 fspf dead-interval Use fspf dead-interval to configure the dead interval for the interface in a specified VSAN. Use undo fspf dead-interval to restore the default. Syntax fspf dead-interval value vsan vsan-id undo fspf dead-interval vsan vsan-id - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 57
Configure the dead interval for interface VFC 1 in VSAN 4 as 100 seconds. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] fspf dead-interval 100 vsan 4 Related commands undo fspf enable Default FSPF is enabled after a VSAN is created. Views VSAN view Predefined user roles network-admin - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 58
to disable FSPF GR Helper. Syntax fspf graceful-restart helper undo fspf graceful-restart helper Default FSPF GR Helper is enabled. Views System view Predefined user roles network-admin Usage guidelines The switch can assist the GR Restarter in completing the GR process only after being enabled with - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 59
fspf graceful-restart helper Related commands • display fspf graceful-restart • fspf graceful-restart fspf graceful-restart interval Use fspf graceful-restart interval to configure the maximum interval for FSPF GR. Use undo fspf graceful-restart interval to restore the default. Syntax fspf graceful - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 60
by the switch to discover and maintain neighbor relationships. The configured Hello interval must commands fspf dead-interval fspf min-ls-arrival Use fspf min-ls-arrival to configure the minimum LSR receiving interval for a specified VSAN. Use undo fspf min-ls-arrival to restore the default - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 61
by LSDB updating. Examples # Configure the configure the minimum LSR refresh interval for a specified VSAN. Use undo fspf min-ls-interval to restore the default. Syntax fspf min-ls-interval value undo fspf min-ls-interval Default The default setting is 5 seconds. Views VSAN view Predefined user - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 62
acknowledgement from the neighbor before retransmitting the LSR. Examples # Configure the LSR retransmission interval for interface VFC 1 in VSAN 4 fspf silent vsan vsan-id Default FSPF is enabled on all interfaces. Views VFC interface view Predefined user roles network-admin Parameters vsan vsan - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 63
spf-hold-time to configure the shortest SPF calculation interval in a specified VSAN. Use undo fspf spf-hold-time to restore the default. Syntax fspf spf-hold-time value undo fspf spf-hold-time Default The default setting is 0 seconds. Views VSAN view Predefined user roles network-admin Parameters - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 64
display fspf statistics FC zone commands delete zone database all Use delete zone database all to delete zone database information. Syntax delete zone database all Views VSAN view Predefined user roles network-admin Usage guidelines You can delete the zone database for the specified VSAN, including - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 65
:22:22:22:22 zone name z2 fcid 0x111111 zone-alias name za1 fcid 0x333333 VSAN 2: VSAN 3: Table 19 Command output Field VSAN fcid pwwn Description VSAN number. FC address of the zone member. pWWN of the zone member. Related commands • member (zone view) • zone clone • zone name • zone rename 60 - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 66
user roles network-admin network-operator Parameters fcid fcid: Specifies a zone member by its FC address, in the format of xxxxxx, where x is a hexadecimal number specified, this command displays parent information for zone members in all VSANs. Usage guidelines You can use this command to display - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 67
display configuration and running status of zones. Syntax display zone status [ vsan vsan-id ] Views Any view Predefined user roles command to display configuration and running status of zones, including zone mode, default zone policy, distribution and merge type, zone database information (numbers - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 68
configuration and running status of zones in all VSANs. display zone status VSAN 1: Mode: basic Default Command output Field VSAN Mode Default zone Distribute Hard-zoning Description VSAN number. Zone mode: basic (supported) or enhanced. Default zone policy: • deny-Members in the default - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 69
, including the numbers of zone sets, zones, and zone aliases in a specific VSAN. Zone status: • merging-Zone merge is in progress. • distributing-Zone distribution is in progress. • database-changing-Data update is in progress. • Free-Idle. Related commands • zone default-zone permit • zoneset - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 70
:22:22:22 zone-alias name za2 fcid 0x111111 VSAN 2: zone-alias name za1 Table 22 Command output Field VSAN fcid pwwn Description VSAN number. FC address of the zone alias. pWWN of the zone alias. Related commands • member (zone-alias view) • zone-alias clone • zone-alias name • zone-alias rename - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 71
name zs1 zone name z1 Table 23 Command output Field VSAN fcid pwwn Description VSAN number. FC address of a zone or a zone alias. pWWN user roles network-admin network-operator Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If no VSAN is specified, this command - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 72
one active zone set. The following rules apply to the command output: • For an existing zone member, which can be queried from the local name service database, this command prefixes an asterisk (*) to the related line. If a pWWN is configured for the zone member, the device queries its associated FC - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 73
*fcid fcid pwwn Description VSAN number. FC address of the zone member that can be queried from the local name service database. FC address of the zone member that does not exist in the local name service database. Configured pWWN of the zone member. Related commands zoneset activate name member - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 74
-z1] member zone-alias za1 Related commands • display zone • display zone member Default No member exists in a zone alias. Views Zone alias view Predefined user roles network-admin Parameters fcid fcid: Specifies the FC address of the member, in the format of xxxxxx, where x is a hexadecimal number - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 75
:08 Related commands • display Default No zone exists in a zone set. Views Zone set view Predefined user roles network-admin Parameters zone-name: Specifies an existing zone, a case-sensitive string of 1 to 64 characters. A zone name can contain English letters (uppercase and lowercase), numbers - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 76
view Predefined user roles uppercase and lowercase), numbers, and special characters commands • display zone • zone name zone default-zone permit Use zone default-zone permit to allow members in the default zone to access each other. Use zone default-zone permit to prohibit members in the default - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 77
Predefined user roles network-admin Examples # Allow members in the default zone to access each other. system-view [Sysname] vsan 1 [Sysname-vsan1] zone default-zone permit Related commands display zone status zone name Use zone name to create a zone and enter its view. If the zone has - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 78
user roles network-admin Parameters old-name: Name of the zone to be renamed, a case-sensitive string of 1 to 64 characters. This name can contain English letters (uppercase and lowercase), numbers z2. [Sysname-vsan1] zone rename z1 z2 Related commands • display zone • zone name zone-alias clone Use - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 79
[Sysname-vsan1] zone-alias clone za1 za2 Related commands • display zone-alias • zone-alias name zone- zone-alias-name Views VSAN view Predefined user roles network-admin Parameters zone-alias-name contain English letters (uppercase and lowercase), numbers, and special characters dollar sign ($), - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 80
user roles network-admin Parameters old-name: Name of the zone alias to be renamed, a case-sensitive string of 1 to 64 characters. This name can contain English letters (uppercase and lowercase), numbers Sysname-vsan1] zone-alias rename za1 za2 Related commands • display zone-alias • zone-alias name - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 81
access control over N_Ports. You must use this command to explicitly activate a zone set as the type specified by the zoneset distribute full command. Examples # Create zone z1. - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 82
English letters (uppercase and lowercase), numbers, and special characters dollar sign user roles network-admin Usage guidelines After activating a zone set as the active zone set by using the zoneset activate command, you can modify the database configuration. With the zoneset distribute command - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 83
distribution type applies to distribution operations triggered by the zoneset activate command instead of the zoneset distribute command. The configured merge type applies to all merge operations. Examples # Configure zone distribution and merge types as complete distribution and complete merge - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 84
user roles network-admin Parameters zoneset-name: Zone set name, a case-sensitive string of 1 to 64 characters. A zone set name can contain English letters (uppercase and lowercase), numbers name zs1 [Sysname-vsan1-zoneset-zs1] Related commands display zoneset zoneset rename Use zoneset rename to - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 85
:6b:60 Vfc2 # Display the number of logged-in nodes on the NPV switch. display npv login vsan 1 count Total entries: 2 Table 25 Command output Field Server Interface External interface FCID Port WWN Description Name of the downlink interface. Name of the uplink interface mapped by the - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 86
and FC address. This command is available only when the switch is operating in NPV mode. Examples # Display the status of the NPV switch in VSAN 1. display npv status vsan 1 External Interfaces: Interface: Vfc1 VSAN tagging mode: Tagging VSAN State FCID 1 Down Number of External - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 87
traffic-map to display the traffic mapping information (downlink-to-uplink interface mappings) of the NPV switch. Syntax display npv traffic-map [ vsan vsan-id ] [ interface interface-type interface-number ] Views Any view Predefined user roles network-admin network-operator Parameters vsan vsan-id - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 88
traffic-map server-interface interface-type interface-number external-interface interface-type interface-number undo npv traffic-map server-interface interface-type interface-number external-interface interface-type interface-number Default No uplink-to-downlink interface mapping is configured. 83 - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 89
interfaces mapped to the downlink interface. If no uplink-to-downlink interface mapping is configured for the downlink interface, it can select an uplink interface to map from all uplink interfaces in the same VSAN. This command is available only when the switch is operating in NPV mode. Examples - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 90
fcid 0xfffc02 Check whether the device with destination address FFFC02 is reachable. 128 data bytes Number of data bytes in each echo request. press CTRL_C to break During the execution of the command, press Ctrl+C to abort the FC ping operation. Reply from 0xfffc02: bytes = 128 time = 0.892 - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 91
the total number of packets sent. Minimum/average/maximum response time, in milliseconds. FC tracert commands fctracert Use bidirectional routing information includes WWNs and domain controller addresses of all switches on a round trip. The device supports a maximum of 255 hops for a round trip. To - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 92
present for press CTRL_C to break 20:00:00:0b:46:00:02:82 0xfffcd5 Fctracert uncompleted. Service is unavailable. Description Path from source to destination. During the execution of the command, press Ctrl+C to abort the FC tracert operation. WWN value. Domain controller address FFFCxx of the - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 93
Acronyms. Websites • HP.com http://www.hp.com • HP Networking http://www.hp.com/go/networking • HP manuals http://www.hp.com/support/manuals • HP download drivers and software http://www.hp.com/support/downloads • HP software depot http://www.software.hp.com • HP Education http://www.hp.com/learn 88 - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 94
Command conventions Convention Boldface Italic [ ] { x | y | ... } [ x | y | ... ] { x | y | ... } * [ x | y | ... ] * & # Description Bold text represents commands bold text. For example, the New User window appears; click OK. Multi-level or damage to hardware or software. An alert that calls - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 95
wired-WLAN switch. Represents an access point. Represents a security product, such as a firewall, a UTM, or a load-balancing or security card that is installed in a device. Represents a security card, such as a firewall card, a load-balancing card, or a NetStream card. Port numbering in examples - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 96
domain configure enable,25 domain restart,25 domain-id,26 F fabric-name,27 fc domain rcf-reject,28 fc mode,7 fc name-service auto-discovery,29 fc route-static,49 fc timer distributed-services,29 fc timer error-detect,30 fc timer resource-allocation,31 fc wwn default-fc4-type,31 fcoe enable,8 fcoe - HP 6125XLG | R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 97
reset counters interface,13 reset fspf counters,58 S shutdown,13 Subscription service,88 T timer distributed-services,33 timer error-detect,34 timer resource-allocation,35 V vsan,38 W Websites,88 wwn area-port-id,36 Z zone clone,71 zone default-zone permit,71 zone name,72 zone rename,72 zone-alias
HP 6125XLG Blade Switch
FCoE
Command Reference
Part number: 5998-3741
Software version: Release 2306
Document version: 6W100-20130912