HP 6125XLG R2306-HP 6125XLG Blade Switch FCoE Command Reference - Page 92

Table 28, Command output, Fabric is being built.

Page 92 highlights

20:00:00:05:30:00:18:db(0xfffcd7) 20:00:00:05:30:00:18:db(0xfffcd7) 20:00:00:0b:46:00:02:82(0xfffcd5) Fctracert completed. Table 28 Command output Field Route present for press CTRL_C to break 20:00:00:0b:46:00:02:82 0xfffcd5 Fctracert uncompleted. Service is unavailable. Description Path from source to destination. During the execution of the command, press Ctrl+C to abort the FC tracert operation. WWN value. Domain controller address FFFCxx of the switch, where xx is the domain ID of the switch. The FC tracert operation fails to be completed for the following possible reasons: • Resource is not enough. • Max hops reached. • Fabric is being built. • No route to destination port. • Destination port is not in fabric. • Destination port and source port are not in the same zone. The FC tracert service is not started, or internal processing fails. 87

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97

87
20:00:00:05:30:00:18:db(0xfffcd7)
20:00:00:05:30:00:18:db(0xfffcd7)
20:00:00:0b:46:00:02:82(0xfffcd5)
Fctracert completed.
Table 28
Command output
Field
Description
Route present for
Path from source to destination.
press CTRL_C to break
During the execution of the command, press
Ctrl+C
to abort the FC tracert
operation.
20:00:00:0b:46:00:02:82
WWN value.
0xfffcd5
Domain controller address FFFCxx of the switch, where xx is the domain ID
of the switch.
Fctracert uncompleted.
The FC tracert operation fails to be completed for the following possible
reasons:
Resource is not enough.
Max hops reached.
Fabric is being built.
No route to destination port.
Destination port is not in fabric.
Destination port and source port are not in the same zone.
Service is unavailable.
The FC tracert service is not started, or internal processing fails.