display fc domain-list, Table 4, Command output

Page 21 highlights

Domain ID: 100 (static) Principal switch running time information: Priority: 2 Path Downstream Downstream Downstream Interface Vfc1 Vfc2 Vfc3 Table 4 Command output Field State Switch WWN Fabric name Priority Domain ID Configuration information Domain configure Domain auto-reconfigure Fabric name Priority Domain ID Principal switch running time information Priority Path Interface Description Running status: • Stable-The configuration is finished. • Unstable-The configuration is not finished. WWN of the local switch. Name of the fabric. Running priority of the local switch. Runtime domain ID of the local switch. Configuration information of the local switch. State of the fabric configuration function: • Enabled-The fabric configuration function is enabled. • Disabled-The fabric configuration function is disabled. State of the auto reconfiguration function: • Enabled-The auto reconfiguration function is enabled on the switch. • Disabled-The auto reconfiguration function is disabled on the switch. Fabric name configured on the switch. Locally configured priority of the switch. Locally configured domain ID. The field in the parentheses can be one of the following: • static-The domain ID is static type. • preferred-The domain ID is preferred type. Runtime information of the principal switch. Running priority of the principal switch. Path type of the interface: • Upstream-Upstream principal link. • Downstream-Downstream principal link. Local VFC interface. display fc domain-list Use display fc domain-list to display the list of domain IDs dynamically assigned in a specified VSAN. 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97

16
Domain ID: 100 (static)
Principal switch running time information:
Priority: 2
Path
Interface
Downstream
Vfc1
Downstream
Vfc2
Downstream
Vfc3
Table 4
Command output
Field
Description
State
Running status:
Stable
—The configuration is finished.
Unstable
—The configuration is not finished.
Switch WWN
WWN of the local switch.
Fabric name
Name of the fabric.
Priority
Running priority of the local switch.
Domain ID
Runtime domain ID of the local switch.
Configuration information
Configuration information of the local switch.
Domain configure
State of the fabric configuration function:
Enabled
—The fabric configuration function is enabled.
Disabled
—The fabric configuration function is disabled.
Domain auto-reconfigure
State of the auto reconfiguration function:
Enabled
—The auto reconfiguration function is enabled on the switch.
Disabled
—The auto reconfiguration function is disabled on the switch.
Fabric name
Fabric name configured on the switch.
Priority
Locally configured priority of the switch.
Domain ID
Locally configured domain ID. The field in the parentheses can be one of the
following:
static
—The domain ID is
static
type.
preferred
—The domain ID is
preferred
type.
Principal switch running time
information
Runtime information of the principal switch.
Priority
Running priority of the principal switch.
Path
Path type of the interface:
Upstream
—Upstream principal link.
Downstream
—Downstream principal link.
Interface
Local VFC interface.
display fc domain-list
Use
display fc domain-list
to display the list of domain IDs dynamically assigned in a specified VSAN.