HP GbE2c HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 50

RMON event information, show rmon event - cross link

Page 50 highlights

The following table describes the RMON Alarm Information parameters. Table 41 RMON Alarm Information Command Index Interval Type rLimit fLimit rEvtIdx fEvtIdx Last value OID Usage Displays the index number that identifies each alarm instance. Displays the time interval over which data is sampled and compared with the rising and falling thresholds. Displays the method of sampling the selected variable and calculating the value to be compared against the thresholds, as follows: abs: absolute value, the value of the selected variable is compared directly with the thresholds at the end of the sampling interval. delta: delta value, the value of the selected variable at the last sample is subtracted from the current value, and the difference compared with the thresholds. Displays the rising threshold for the sampled statistic. Displays the falling threshold for the sampled statistic. Displays the rising alarm event index that is triggered when a rising threshold is crossed. Displays the falling alarm event index that is triggered when a falling threshold is crossed. Displays the last sampled value. Displays the MIB Object Identifier for each alarm index. RMON event information The following command displays RMON event information: show rmon event Command mode: All RMON Event group configuration: Index ----- 1 2 3 4 5 10 11 15 100 Type ---both none log trap both both both both both Last Sent 0D: 0H: 1M:20S 0D: 0H: 0M: 0S 0D: 0H: 0M: 0S 0D: 0H: 0M: 0S 0D: 0H: 0M: 0S 0D: 0H: 0M: 0S 0D: 0H: 0M: 0S 0D: 0H: 0M: 0S 0D: 0H: 0M: 0S Description Event_1 Event_2 Event_3 Event_4 Log and trap event for Link Down Log and trap event for Link Up Send log and trap for icmpInMsg Send log and trap for icmpInEchos Event_100 The following table describes the RMON Event Information parameters. Table 42 RMON Event Information Command Index Type Last Sent Description Usage Displays the index number that identifies each event instance. Displays the type of notification provided for this event, as follows: log, trap, both. Displays the time that passed since the last switch reboot, when the most recent event was triggered. This value is cleared when the switch reboots. Displays a text description of the event. Information Commands 50

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153

Information Commands 50
The following table describes the RMON Alarm Information parameters.
Table 41
RMON Alarm Information
Command
Usage
Index
Displays the index number that identifies each alarm instance.
Interval
Displays the time interval over which data is sampled and compared with the rising and falling
thresholds.
Type
Displays the method of sampling the selected variable and calculating the value to be compared
against the thresholds, as follows:
abs
: absolute value, the value of the selected variable is compared directly with the thresholds at the
end of the sampling interval.
delta
: delta value, the value of the selected variable at the last sample is subtracted from the current
value, and the difference compared with the thresholds.
rLimit
Displays the rising threshold for the sampled statistic.
fLimit
Displays the falling threshold for the sampled statistic.
rEvtIdx
Displays the rising alarm event index that is triggered when a rising threshold is crossed.
fEvtIdx
Displays the falling alarm event index that is triggered when a falling threshold is crossed.
Last value
Displays the last sampled value.
OID
Displays the MIB Object Identifier for each alarm index.
RMON event information
The following command displays RMON event information:
show rmon event
Command mode:
All
RMON Event group configuration:
Index
Type
Last Sent
Description
-----
----
----------------
---------------------------------
1
both
0D: 0H: 1M:20S
Event_1
2
none
0D: 0H: 0M: 0S
Event_2
3
log
0D: 0H: 0M: 0S
Event_3
4
trap
0D: 0H: 0M: 0S
Event_4
5
both
0D: 0H: 0M: 0S
Log and trap event for Link Down
10
both
0D: 0H: 0M: 0S
Log and trap event for Link Up
11
both
0D: 0H: 0M: 0S
Send log and trap for icmpInMsg
15
both
0D: 0H: 0M: 0S
Send log and trap for icmpInEchos
100
both
0D: 0H: 0M: 0S
Event_100
The following table describes the RMON Event Information parameters.
Table 42
RMON Event Information
Command
Usage
Index
Displays the index number that identifies each event instance.
Type
Displays the type of notification provided for this event, as follows:
log, trap, both
.
Last Sent
Displays the time that passed since the last switch reboot, when the most recent event was triggered.
This value is cleared when the switch reboots.
Description
Displays a text description of the event.